ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
ISE20B : 0x02440x1450 Z/ISE20B 0x0BB8 (3000) P_1(n_1) (5805200) 0x03F4 (1012) 0 R/W (Setting of switch U16 ZSE20B : 0x02580x1450 (6005200) ZSE20BF : 0x03840x13EC (9005100) ZSE20BF point of OUT1) 0x0FA0 (4000) ISE20B 0x04B0 (1200) Setting of OUT1 hysteresis.
Settable range of user set value Settable value range Range Lower limit Upper limit -10..+10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..+5 V -5.25 to +5.22 V -5.22 to +5.25 V -20..+20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00
Settable range of user set value Settable value range Range Lower limit Upper limit -10..+10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..+5 V -5.25 to +5.22 V -5.22 to +5.25 V -20..+20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00
IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.
Units specification Pressure range Default setting ISE20B: 0.050 MPa/ZSE20B: 5.0 kPa/ ZSE20BF: 5.0 kPa Hysteresis ISE20B MPa "Nil" or M ZSE20B(F) kPa Delay time 0.00 sec.
ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.
ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.
ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
ISE20B-L is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -
Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -