If an adsorption confirmation switch is replaced for a vacuum switch on ZX1071-K15LZ-PBC, indicate as ZSE2-0X-15C-D. In this case, mounting screws P3270148-49 (2 pcs.) are required. If the unit is used on its own, not combined with others, D is not required. Ex.)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: C (Connector Style Lead Wire Length 0.6m)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: CN (w/o Connector)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 15 (NPN Open Collector 1 Output)
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: Connector Style Lead Wire Length 0.6m
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: NPN Open Collector 1 Output, Wiring Specification: Grommet Lead Wire 3m
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: -
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: Connector Style Lead Wire Length 3.0m
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: Grommet Lead Wire 3m
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: w/o Connector
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: NPN Open Collector 1 Output, Wiring Specification: -
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: L (Grommet Lead Wire 3m)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 15 (NPN Open Collector 1 Output), Wiring Specification: L (Grommet Lead Wire 3m)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: CL (Connector Style Lead Wire Length 3.0m)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output)
energy saving function series Winter Ambient temperature: 36F (2C) Inlet air temperature: 50F (10C) Set dew point: 50F (10C) Conditions Summer 104F Energy saving operation mode 38% reduced 38% reduced Double energy saving function series (40C) Ambient temperature: 104F (40C) Inlet air temperature: 122F (50C) Set dew point: 86F (30C) Conditions Refer to page 3 for dew point change. 59C (15C
Note 2) Series IDF Inlet air temperature: Saturated at 35C (IDF1D), saturated at 40C (IDF2D to 240D), Ambient temperature: 32C Note 3) Series IDG Inlet air temperature: Saturated at 25C, Ambient temperature: 25C Note 4) Series IDU Inlet air temperature: 60C (IDU3D to 6D), 55C (IDU8D to 37C1), 50C (IDU55C, 75C), Ambient temperature: 32C Note 5) means voltage indication symbol (IDF3D to 15C
IDF6E to 15E1 Max. operating pressure *4 1.0 MPa Max. operating temperature 60C Conversion bypass piping set [When there is no bypass piping] For ensuring conversion to the former models (IDF6D to 15C) air piping.
(2) DC24V NFB MC M (3) IEC60664-12 (IP54) A 10 (4) (a) YIEC60664-1 400V (b) DC24V (5) (a) (PE) () (PE) (b) (PE) () 1 PE PE PE PE (c) (PE) () (6) (a) (b) EN (7) (a) EN/IEC B() A B (b) EN60204-15C 40 PVC() (c) EMC (8) EMC EMC () EMCEMC(IB()67303) A 11 UL/C-UL (1) LECSSLE-S5-LE-S6-LE-S7-LE-S8() .
Valve Temperature Range: Standard Valves 5F ( 15C) to 122 F (50 C) ambient; media. .63 (16.0) .86 (21.8) BOTTOM VIEW Maximum Operating Pressure Differentials: See catalog listings Burst Pressure: 1500 PSI Leakage: Bubble tight for standard valves Vacuum: To 5 Microns Consult factory Coil Voltage: 6 to 220 VAC 50-60 Hz. 2 to 150V DC.