Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: NPN Open Collector 1 Output, Wiring Specification: w/o Connector
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: NPN Open Collector 1 Output, Wiring Specification: -
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: L (Grommet Lead Wire 3m)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 15 (NPN Open Collector 1 Output), Wiring Specification: L (Grommet Lead Wire 3m)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 15 (NPN Open Collector 1 Output), Wiring Specification: CL (Connector Style Lead Wire Length 3.0m)
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output)
The ambient temperature range is 0 to 55C for the ionizer. Do not use the product in locations where the ambient temperature changes suddenly even within the specifications or if the temperature difference of the fluid relative to the ambient temperature is large condensation may occur. 5.
Pressure Range: 0~0.97MPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, w/o Analog Output, 200° Setting, Wiring Specification: Connector Style Lead Wire Length 0.6m
Pressure Range: 0~100kPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, w/o Analog Output, 200° Setting, Wiring Specification: Connector Style Lead Wire Length 0.6m
Pressure Range: L (0~100kPa), Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output, w/o Analog Output, 200° Setting), Wiring Specification: C (Connector Style Lead Wire Length 0.6m)
Pressure Range: 0~1MPa, Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: C (Connector Style Lead Wire Length 0.6m)
Piping Specification: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output, w/o Analog Output, 200° Setting), Wiring Specification: C (Plug Connector; Lead Wire 0.6m)
Piping Specification: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output), Wiring Specification: C (Connector Style Lead Wire Length 0.6m)
Pressure Range: 0~0.97MPa, Port Size: T1 (Single Unit Mounting NPTF 1/8), Output Specification: 55 (PNP Open Collector 1 Output, w/o Analog Output, 200° Setting), Wiring Specification: C (Connector Style Lead Wire Length 0.6m)
Pressure Range: 0~1MPa, Port Size: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: Connector Style Lead Wire Length 0.6m
Piping Specification: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, Wiring Specification: Connector Style Lead Wire Length 0.6m
Piping Specification: Single Unit Mounting NPTF 1/8, Output Specification: PNP Open Collector 1 Output, w/o Analog Output, 200° Setting, Wiring Specification: Plug Connector; Lead Wire 0.6m
Operate in an environment in the specified ambient temperature and fluid temperature ranges (0 to 55C). Avoid sudden temperature changes even within specified temperature range, as it may cause condensation. 2. Do not use this product in an enclosed space. This product utilizes the corona discharge phenomenon. Although the amount is very small, Ozone and NOx are generated.
compressor output (Guide) In case of screw type (kW) Port size Pages Refrigerant Rated inlet condition IDF1E IDF2E IDF3E IDF4E IDF6E IDF8E IDF11E 0.12 0.235 0.37 0.57 0.82 1.32 1.82 0.10 0.20 0.32 0.52 0.75 1.22 1.65 0.75 1.5 2.2 3.7 5.5 7.5 11 Rc3/8 Standard inlet air temperature Saturation: 35C 0.7MPa HFC134a P.2-P.4 Rc1/2 IDF Rc3/4 IDU3E IDU4E IDU6E High inlet air temperature Saturation: 55C
AL09 FLT 55C AL10 OFF *1 40C 3 CH1 Hgih Temp. AL11 CH1 Low Temp. OFF *1 10C 3 Check the effect of ambient temperature. Please review the setting value. There may be causes such as large load fluctuation and flow rate fluctuation. Please review the setting value. AL12 CH1 TEMP READY ALARM OFF *1 +1/-1C 3 CH2 High Temp.