This is a legacy product, and replaced byISE78G-02-L2-M, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .56564 lb
This is a legacy product, and replaced byISE78G-02-L2-MLA ISE70/75 PRESSURE SWITCH. PRESSURE SWITCH, DIGITAL. INSTRUMENTATION. ISE70/75 1/4 PT VERSION. 1.00508 lb. DA.
This is a legacy product, and replaced byISE78G-02-L2-MLA ISE70/75 PRESSURE SWITCH. PRESSURE SWITCH, DIGITAL. INSTRUMENTATION. ISE70/75 1/4 PT VERSION. 1.23458 lb. DA.
This is a legacy product, and replaced byISE78G-02-L2-M ISE70/75 PRESSURE SWITCH. PRESSURE SWITCH, DIGITAL. INSTRUMENTATION. ISE70/75 1/4" PT VERSION. .71773 lb. DA.
This is a legacy product, and replaced byISE78G-02-L2 ISE70/75 PRESSURE SWITCH. PRESSURE SWITCH, DIGITAL. INSTRUMENTATION. ISE70/75 1/4" PT VERSION. .66138 lb. DA.
:ti Statlons 02-2 stations System type. AEjectors B External Vacuum 'For plug (X) posirioning onty.
'-02 ~2 06 >6 (Application: Refer to ListO) i 08 ~8 U Flat type Material a With buffer 04 4 Pad type.
Number of needle rotations Dimensions D3 Applicable tubing O.D. d D1 L3 A L4 M T H (Width across flats) L2 L1 Metric Size/Inch Size [mm] Model d T H D1 D3 L1 L2 L3 L41 A2 M Weight [g] Unlocked Locked Unlocked Locked AS121F-M3-02A-X790 2 11.9 5 AS121F-M3-23A-X790 3.2 7.2 17.2 21.7 5.8 15.8 20.3 16.9 13.3 AS121F-M3-04A-X790 4 8.2 AS121F-M3-06A-X790 6 10.4 18.6 23.1 16.5 6 AS121F-M3-01A-X790
Poriing No. of Ports 'xx" M84010-02 Ta"NPTFSide l l M84011-02 7a" NPTF Side: Y.r" Bottom A & B 1 3 MB 4210-02 %"NPTFSid(2); % Botlom(5) 7 t 5 Manifolds *(OptionsT & P Only) Part No. Poding No.of Ports "xx" Subplates .
ljmjlllqleto') AR20 to 60, AR20K to 60K _ Nol 1)Bracketassembty,s ml molnled atthe tne oj shipment Dlt @ther packaged logether ur lh rhe @gulator Nole2)Nlounlinalhreadslorpressurqalge:A810 1/16 AF201o30-1rB AF40lo60 1/4.
(station 4) Noter Order lett to right (station 1-10) facing tension bolt & filter cover 52 IIIZM $eri Manifold Dimensions inch (mm NZZM05-T068 ) t n: station L1 1 .73 @4\ 2.36 (60) 2.99 (76) 3.62 (92) 4.2s (108) 4.88 (124) 5,51 (140) 6.14 (156) 6.77 (172\ L2 2.20 (56) 2.83 (72\ 3.46 (88) 4.09 (104) 4.72 (1201 s.35 (136) 5.98 (1s2) 6.61 (168) 7.24 (18r'.
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: B (Bracket B), Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type])
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: 02 (Rc 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)