Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70), Operation
However, the SY3000 cannot be mounted onto the SY7000 series. q Series w Connector type r Valve stations 5 7 Symbol Type Page SY5000 SY7000 Symbol Stations Note F FW P PG PH J G T L1 L2 L3 M S S6 S S S4 S3 02 IP40 IP67 26 pins 20 pins 10 pins Some connectors have a limitation on the number of stations.
valves there is no S option.
How to Order Sub-plate Assembly System Components System Solenoid valve Speed controller Silencer Tube bore x Length Pilot type Nil R External pilot Internal pilot AS2000-01 (S = 2.5 mm2) AN110-01 (S = 35 mm2) AS3000-02 (S = 12 mm2) AN110-01 (S = 35 mm2) AS3000-02 (S = 12 mm2) AN110-01 (S = 35 mm2) AS4000-02 (S = 21 mm2) AN110-01 (S = 35 mm2) AS4000-02 (S = 21 mm2) AN110-01 (S = 35 mm2) T0425
01(R) Note 1) Option Note 2) When two or more symbols are specified, indicate them alphabetically. (2) 01 [Rc 1/8] 02 [Rc 1/4] 02 [Rc 1/4] 03 [Rc 3/8] VQZ200 VQZ200-S(2) VQZ300 VQZ300-S(2) Note) Symbol R indicates an external pilot.
(16 outputs) S-Link (8 outputs) T Link Mini DeviceNet CompoBus/S (16 outputs) CompoBus/S (8 outputs) JEMANET J1 J2 K Q R1 R2 U V CC-Link SS5Y3-45SA-05U-C6. 1 set (Type 45S, 5 station manifold base with serial unit part no.)
How to Order KQ2 H 05 S 02 With thread seal One-touch fittings Nil Without seal S With thread seal Applicable tubing O.D.
www.stevenengineering.com I 7.23 INSTRUMENTATION ELECTRO-PNEUMATIC REGULATOR D I M E N S I O N S S E R I E S VY110 0 101 02 D I M E N S I O N S S E R I E S VY120 0 101 02 D I M E N S I O N S S E R I E S VY130 0 102 03 04 Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 !
Orifice symbol (diameter) Solenoid valve (Port size) DC 1 (2 mm) 2 (3 mm) 3 (4.5 mm) 4 (6mm) VX21 VX22 VX23 Model Class H 01 ( ) 02 ( ) 1 8 Rated voltage S L Z 1 4 02 ( ) 03 ( ) 02 ( ) 03 ( ) Port no.
Connection L2 M d A Effective area (mm2) Weight (g) L1 thread R Model 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFH04-01 KFH04-02 KFH06-01 KFH06-02 KFH06-03 KFH08U-01 KFH08U-02 KFH08U-03 KFH08N-01 KFH08N-02 KFH08N-03 KFH10U-02 KFH10U-03 KFH10U-04 KFH10N-02 KFH10N-03 KFH10N-04 KFH12U-02 KFH12U-03 KFH12U-04 KFH12N-02 KFH12N-03 KFH12N-04 10 10
P P C C U U O O S S L L H H 8 3 11.5 5 L2 dimension Stations 1 2 3 4 5 6 7 8 9 M DIN rail part no.
02 03 1 4 S 5 VDC 5 3 position pressure center Note 1) : Enter a symbol for cable length.
08 8 stations 02 2 stations Specified layout2 (Up to18 solenoids available) (Up to 16 solenoids available) 18 18 stations For 16 output points (L2/Sm/S3m) 16 16 stations For 8 output points (PH/PHC/L3) EX600 63 Sm EX245 73 Sm EX250 77 Sm EX260 83 S3m EX120 91 Symbol Stations Note 02 2 stations Double wiring1 Symbol Stations Note 02 2 stations Double wiring1 t I/O unit stations (S6m)
ASR430F-02-08S(-F20) ASR430F-02-10S(-F20) ASR530F-02-06S(-F20) ASR530F-02-08S(-F20) ASR530F-02-10S(-F20) ASR530F-02-12S(-F20) ASR530F-03-06S(-F20) ASR530F-03-08S(-F20) ASR530F-03-10S(-F20) ASR530F-03-12S(-F20) ASR630F-03-10S(-F20) ASR630F-03-12S(-F20) ASR630F-04-10S(-F20) ASR630F-04-12S(-F20) ASQ430F-02-06S(-F20) ASQ430F-02-08S(-F20) ASQ430F-02-10S(-F20) ASQ530F-02-06S(-F20) ASQ530F-02-08S
8 stations 4 stations 02 2 stations 02 2 stations 02 2 stations (2) (2) (2) Applicable up to 20 solenoids.
(type J1) 8 outputs (type J2) a) T type branch multi-drop wiring (S-LINK System) b) Crossover wiring (Sensor Link System) DG Power supply 24V 0V 0V 24V G D G D SI unit SI unit Master unit D 0V 24V G D 0V 24V G D 0V 24V G D 0V 24V L2 L1 G Power supply 24V 0V LINE1 LINE2 SHIELD L1 L2 0V 24V Transmission lines SHIELD SHIELD L1 L2 FG 24V 0V L1 L2 FG 24V 0V Black White Brown Blue Terminal resistor