-*309(0x0135) ISE75G-*-L2-*320(0x0140) ISE76G-*-L2-*321(0x0141) ISE77G-*-L2-*322(0x0142) ID ISE78G-*-L2-*362(0x016A) 1(0 ms) 2 3 ISE70G/ISE75G MPa/kPa ISE76G/ISE77G/ISE78G MPa 490 5https://www.smcworld.com 6 02 N02 F02 Rc1/4 NPT1/4 G1/4 Al2O3(96) ISE70GC3604()FKM+ ISE75G/ISE76G/ISE77G/ISE78GC3604()FKM ISE70G 179 g 178 g 175 g ISE75G/ISE76G/ISE77G 184 g 183 g 181 g M12 139 g -87No.PS-OMV0008CN-E

SA SA/ /INP PD13 23 O ZSP ZSP ZSP ZSP ZSP ZSP PD14 24 O INP INP/SA SA SA/ /INP PD15 25 O TLC TLC TLC TLC/VLC VLC VLC/TLC PD16 26 (Note 3) (Note 3) 27 I TLA (Note 3) TLA/TC TC TC/TLA TLA TLA 28 LG LG LG LG LG LG 29 30 LG LG LG LG LG LG 31 32 33 O OP OP OP OP OP OP 34 LG LG LG LG LG LG 35 I NP NP/ /NP 36 I NG NG/ /NG 37 38 39 40 41 I CR CR/SP1 SP1 SP1/SP1 SP1 SP1/CR PD08 42 I EMG EMG EMG EMG

Electrical entry LO MO L plug connector without connector M plug connector without connector Note 1) Plug connector and lead wire layers are attached to the manifold. 2-4-55 S VQ0/1000/2000 Kit (Serial transmission unit) VQ0 L2 L1 P = 10.5 12.5 5.2 65 65 141 49 (L plug connector) 1.5 1.5 43 (M plug connector) Indicator light Lead wire length 300 mm The DWG shows the SA type (General type)

Reference dimensions of 10-32 UNF and NPT threads after installation. 15-9-79 6 Dimensions Universal type L6 D4 Applicable tubing O.D. d H D1 (Hexagon width across flats) M1 L3 A L4 L5 D3 L1 D2 T L2 Metric Size Inch Size A Model A D1 d T H D2 D3 D4 L1 L2 L3 L4 L5 L6 M1 d T H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 Model M1 AS131F-M5-23D AS131F-U10/32-01D 1/8" 8.4 3.2 8.4 19.8 19.8 12.7 17.5 28.7

Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3

AS-T D1 ASP L3 ASN AQ ASV AK D2 T1 L1 VCHC ASR ASQ Dimensions A Weight (g) AS120-U10/32-D 10-32 UNF 10-32 UNF AS120-M5-D M5 x 0.8 8 9 M5 x 0.8 Model T2 H D1 T1 D2 D3 L3 L4 L1 L2 9 4.7 10 31 10.3 0.7 27.4 13 AS220-N01-SD NPT 1/8 12.7 NPT 1/8 AS220-F01-SD G 1/8 AS220-01-SD Rc 1/8 12 14.3 R 1/8 14.6 7.2 18 34.7 13.2 1.2 31.6 33 AS220-N02-SD NPT 1/4 17.5 NPT 1/4 AS220-F02-SD G 1/4 AS220-02-

P S T Speed reached SA CN1-10 SA turns on when the servo motor speed has nearly reached the preset DO-1 speed. When the preset speed is 20r/min or less, SA always turns on.

8 stations) 1 2 3 4 5 6 7 8 L n 39 48.5 75 85.5 49.5 59 87.5 98 60 69.5 87.5 98 70.5 80 100 110.5 81 90.5 112.5 123 91.5 101 125 135.5 102 111.5 137.5 148 112.5 122 150 160.5 L1 L2 (L3) (L4) Vacuum ejector unit style: Formula L1 = 10.5n + 28.5 + (Number of ejector units x 26.7) L2 = 10.5n + 38 + (Number of ejector units x 26.7) L4 is L2 plus about 30. 2-4-152 Base Mounted Series VQ1000/2000

Size Mounting bracket 25 32 40 50 63 Foot Note 1) MU-L02 MU-L03 MU-L04 MU-L05 MU-L06 Rod flange MU-F02 MU-F03 MU-F04 MU-F05 MU-F06 Note 1) When ordering foot bracket, order 2 pieces per cylinder. Note 2) Body mounting bolts are attached to the foot and rod flange. Note 3) The tightening torque for body mounting bolts is shown in the below table.

(a) Delta connection For the 3-phase (L1/L2/L3) delta connection, an instantaneous power failure occurs in the voltage between a pair of lines (e.g. between L1 and L2) among voltages between three pairs of lines (between L1 and L2, L2 and L3, or L3 and L1).

DO-1 Speed reached SA When using this signal, make it usable by the setting of parameter No.PD07 to PD09. When the servo is off, SA will be turned OFF. When servo motor rotation speed becomes approximately setting speed, SA will be turned ON. When the preset speed is 20r/min or less, SA always turns on. This signal cannot be used in position loop mode.

Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.

Speed reached SA SA will turn off during servo-off. When the servo motor speed reaches the following range, SA will turn on. Set speed ((Set speed 0.05) + 20) r/min When the preset speed is 20 r/min or less, SA always turns on. The device cannot be used in the position control mode and torque control mode.

Abbreviation Connection target (application) Description Supply the following power to L1, L2, L3. For the 1-phase 200 to 230VAC power supply, connect the power supply to L1, L2, and keep L3 open.

Symbol L1 L2 Calculation formula: L1 = 26n + 24, L2 = 26n + 12 Calculation formula: L1 = 26n + 36, L2 = 26n + 10 5-5-7 4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 5-5-8 5 3 Port Air Operated Valve Series VTA315 How to Order SA VTA315 VA SA Port size Indicate

AC200230V AC100120V 40 M5 3.24[Nm] M5 3.24[Nm] 6 AC100120V AC200230V AC100120V AC200230V L1 L1 PE PE L2 2-M5 2-M5 L2 L3 CNP1 CNP1 N N P1 P1 M4 1.2[Nm] P2 P2 M4 1.2[Nm] P P C C CNP2 D CNP2 D L11 L11 L21 L21 U U CNP3 V CNP3 V W W 9 2 9 (2) LECSS-S8 [mm] 5 40 6 6 6 (80) (170) 6 6 () CN4 CN2L CN2 CN1B CN1A CN3 CN5 CNP1 L1 L2 L3 N P1 P2 P C D L11 L21 U V W L1 L2 () L3 N P1 CNP2 P2

(L3) (L4) Vacuum ejector unit style: Equation L1=10.5n+28.7+(number of ejector units X 26.7) L2=10.5n+41.3+(number of ejector units X 26.7) L4 is L2 plus about 30.

400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 2000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 2 Standard Motor/Horizontal Mount Specification Series LJ1H10 Dimensions/LJ1H101PB Scale: 15% 10 6 Work piece mounting reference plane LJ1 LG1 LX LC6D/LC6C Switches LC1 80 5H10

CG1 series GC GD W C port C port D port B port A port D port W H SB + Stroke SA + Stroke ZZ + 2 x Stroke CG1 (mm) CG1K (mm) Bore size GC GD H SA SB W ZZ Long stroke Note) SA ZZ 20 21 9 35 48 87 30 172 56 180 25 21 9 40 48 87 30 177 56 185 32 23 9 40 50 91 30 183 58 191 40 25 9 50 56 100 20 208 65 217 50 29 13 58 63 118 20 241 75 253 63 28 12 58 64 117 20 241 76 253 Bore size GC GD H SA SB

Stations U side D side 8 one-touch fitting 7 6 15 14 1 0 10 one-touch fitting 9 8 Mixture of port sizes VV5QZ25-SA07C6 One-touch fitting (Inch size) Symbol N1 N3 N7 N9 N11 NM Port size VQZ1000 VQZ2000 VQZ3000 1/8" one-touch fitting 5/32" one-touch fitting 1/4" one-touch fitting VV5QZ25-SA07C6 1 set (Type SA, 7-station manifold base part no.)