Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70),
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE71 (0 to 1.6 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: None, Operation Manual/Calibration Certificate
) 16-2-51 8 Series ISE70/75/75H Pressure Switch Precautions Be sure to read before handling.
ISE70 ZSE80 ISE80 Terminal block box ZSE ISE ZSP PS ISA2 ISA2 With regulator + 2 port solenoid valve PSE With 2 port solenoid valve IS ISG ZSM1 Check optimum position at a glance.
Dimensions Space saving branch tee: LQ3T-SB Metric Size (L2, L2) 2 x B Model Applicable tubing O.D.
AC200230V AC100120V 40 M5 3.24[Nm] M5 3.24[Nm] 6 AC100120V AC200230V AC100120V AC200230V L1 L1 PE PE L2 2-M5 2-M5 L2 L3 CNP1 CNP1 N N P1 P1 M4 1.2[Nm] P2 P2 M4 1.2[Nm] P P C C CNP2 D CNP2 D L11 L11 L21 L21 U U CNP3 V CNP3 V W W 9 2 9 (2) LECSS-S8 [mm] 5 40 6 6 6 (80) (170) 6 6 () CN4 CN2L CN2 CN1B CN1A CN3 CN5 CNP1 L1 L2 L3 N P1 P2 P C D L11 L21 U V W L1 L2 () L3 N P1 CNP2 P2
side mounting 17.5 17.5 3 1/8" PE. port 3 1/8" PE. port 38 70 38 53 Dimensions Formula: L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) Dimensions Formula: L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) n L 1 2 3 4 5 6 7 8 L1 88 113 138 163 188 213 238 263 L2 101 126 151 176 201 226 251 276 n L 1 2 3 4 5 6 7 8 L1 88 113 138 163 188 213 238 263 L2 101 126 151
(L3) (L4) Vacuum ejector unit style: Equation L1=10.5n+28.7+(number of ejector units X 26.7) L2=10.5n+41.3+(number of ejector units X 26.7) L4 is L2 plus about 30.
400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 2000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 2 Standard Motor/Horizontal Mount Specification Series LJ1H10 Dimensions/LJ1H101PB Scale: 15% 10 6 Work piece mounting reference plane LJ1 LG1 LX LC6D/LC6C Switches LC1 80 5H10
Solid state auto switch : D-H7, D-H7C, D-H7W, D-H7NF, D-H7BA Reed auto switch : D-C7, D-C80, D-C73C, D-C80C, D-A80, D-A9, D-A9V, D-A79W, D-A73 CM2 series C port Stroke A Stroke B A port B port (mm) Bore size (mm) SA SB ZZ 20 48 62 164 25 48 62 168 32 50 64 172 SA + Stroke A SB + Stroke B 40 67.5 88.5 222 ZZ + Stroke (A + B) CM2R series A port B port C port (mm) Bore size (mm) SA SB ZZ 20
n Dimensions 8 263 276 L1 L2 7 238 251 8 263 276 L1 L2 6 213 226 7 238 251 5 188 201 6 213 226 4 163 176 5 188 201 3 138 151 4 163 176 1 2 113 126 3 138 151 1 2 113 126 88 101 88 101 L n L n 9 288 301 15 463 476 14 413 426 13 388 401 12 363 376 11 338 351 10 313 326 9 288 301 16 463 476 15 463 476 14 413 426 13 388 401 12 363 376 11 338 351 10 313 326 16 463 476 L1 L2 L1 L2 2-5-37 Base Mounted
Allowable Moment (Nm) Allowable dynamic moment Allowable static moment Pitching Rolling Yawing 4 3 4 LXF Model Load movement direction a = 1000 2000 a Mep a = 2000 L1 (mm) Pitching Rolling Yawing a = 3000 m : Transfer load (kg) L : Overhang to work piece center of gravity (mm) a : Work piece acceleration (mm/sec) Me: Dynamic moment 1000 m L1 3 0 1 2 Transfer load m (kg) a = 1000 300 L2 (mm
400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 2000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 2 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
B 2 A 4 6 B 2 A 4 SMC SMC SMC SMC SMC 5 Cable length B 2 A 4 4 L2 L1 B 2 A 4 3 B 2 A 4 2 P=41 34.5 48 P=41 B 2 A 4 1 58.5 68.5 X 12 Stations D side 42 16 15.5 22 107.8 51 179 117 69 Electrical entry on D side (LD) 2-1/8 (external pilot port) Dimensions Formulas: L1 = 41n + 76, L2 = 41n + 96 L n 9 445 465 8 404 424 L1 L2 7 363 383 6 322 342 5 281 301 4 240 260 3 199 219 2 158 178 1 117 137
Uni thread H D1 D2 L1 L2 L5 A Max.
/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) ISE70/ISE75(H) () 1 ON ON OFF Yes No 2 OFF ON 1 OFF 3 4 5 -26No.PS-OMH0002CN-D 6 Yes No 7 7 8 9 10 11 12 13 14 15 -27No.PS-OMH0002CN-D No.