F1 -X L2 L1 50 50 50 L3 2040 40 40 30 30 30 Data 20 20 20
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
Yaw moment M3 = W4 x L2 YES L2 Is there any influence of noise? (Refer to Caution on Handling on pages 706 and 707.) Install a noise filter. NO M3 There is no particular problem in using the system.
) L2 a = 2000 200 a = 3000 100 Mer m 3 0 1 2 Transfer load m (kg) a = 1000 a 2000 a = 2000 Mey L3 (mm) a = 3000 m 1000 L3 3 0 2 1 Transfer load m (kg) Refer to page 304 for deflection data. 210 5 Phase Stepper Motor/Without Motor Brake Series LXF Dimensions/LXFH5BC Scale: 35% (5) 2-M2.5 x 0.45 depth 2 5 Stroke + 113 10.5 2.5 2-M4 x 0.7 thread depth 9 31 G 28 58 5H9 +0.030 0 depth 5 (5.5)
Yaw moment M3 = W4 x L2 L2 Data YES Is there any influence of noise? (Refer to Caution on Handling on pages 6 and 7.) Install a noise filter.
Yaw moment M3 = W4 x L2 L2 Data YES Is there any influence of noise? (Refer to Caution on Handling on pages 6 and 7.) Install a noise filter.
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: B (Bracket B)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate: Y (None)
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: -, Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE75[H], Operation Manual/Calibration Certificate: -
Pressure Range: 0 to 10 MPa, Piping: Rc 1/4, Orifice: None, Unit Specification: SI Unit Only, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -