M3E = 1/3 x FE x Y = 1/3 x 188.7 x 25/1000 = 1.6 [Nm] 3B = M3E/M3max = 1.6/17.1 = 0.09 M3 Refer to [3] Calculation for Overall Center of Gravity in the Y-axis on front matter 7.
SOL.A 2A SV Station 2 SOL.B 2B SOL.A 3A Station 3 SOL.B SYJ 3B SOL.A 4A Step 2. Wiring Loosen screws on the terminal block, connect wiring and complete it by tightening screws.(Tightening torque: 0.5 to 0.7 Nm) The diagram on the right shows the terminal block wiring. All stations are provided with double wiring regardless of the valves which are mounted.
MSUA7-180 P402060-3B MSUA2090 P402080-3A MSUA20-180 P402080-3B Note 1) Note that the rotation angle should not be changed even though the rotary unit has been changed. For maintenance, order units with a part number suitable for the model being used.
M3 3B = M3E/M3E max = 1.8/10 = 0.18 L2 M3E m x g FE From above, n = 1 + 2a + 2b + 3A + 3B = 0.25 + 0.105 + 0.084 + 0.225 + 0.18 = 0.844 From n = 0.844 1, it is applicable. 8-16-10 10 MX MTS MY CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX D-X 20Data 8-
IDF1E 0.75 Rc3/8 IDF2E 1.5 IDF3E 2.2 IDF4E 3.7 Rc1/2 IDF6E 5.5 Rc3/4 IDF8E 7.5 IDF11E 11 IDF15E1 15 Rc1 IDF22E 22 R1 IDF37E 37 R1 1/2 IDF55E 40C 0.7 MPa 55 R2 IDF75E 75 35C 0.7 MPa Model Rated inlet condition Applicable air compressor [kW] Port size IDF100F 100 R2 IDF125F 125 65 (2 1/2B) Flange IDF150F 150 80 (3B) Flange IDF190D 190 IDF240D 240 100 (4B) Flange IDFlE 40C 0.7 MPa IDF370D 35C
Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. 0 1 With relief valve None Port size Symbol Flange SSA 15 (1/2B) 20 (3/4B) 25 (1B) 32 (1 1/4B) 40 (1 1/2B) 50 (2B) 65 (2 1/2B) 80 (3B) Threaded Rc 3/8 1/2 3/4 1 1 1/4 1 1/2 03 04 06 08 10 12 16 20 24 Replacement Element Part No.
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model/Rated Flow Rate Model Port size Note 2) INLET OUTLET Rated flow rate (L/min) FH990-04 FH990-06 FH990-08 FH990-10 FH990-12 FH990-16 FH991-20 FH991-24 FH991-28 FH991-32 1B 1/2B 20 1B 3/4B 50 1 1/2B 1B 100 1 1/2B 1 1/4B 150 2B 1 1/2B 200 2B 2B 300 2 1/2B 2 1/2B 450 3B 3B 600 3 1/2B 3 1/2B 750 4B 4B 900 Note 2) Both flange
COM (+) () (+) () SOL.A 1A Station 1 (+) () SOL.B 1B (+) () SOL.A 2A Station 2 (+) () SOL.B 2B (+) () SOL.A 3A Station 3 (+) () SOL.B 3B (+) () SOL.A 4A M2.5 Station 4 (+) () SOL.B 4B (+) () SOL.A 5A Cover 1st row 3rd row 2nd row -Step 2. Wiring The diagram on the left shows the terminal block wiring schematic. All stations are provided with double solenoid wiring.
HRX-OM-X084 Chapter 8 Control, Inspection, Exchange and Cleaning HRR Series 8.4 Replacement of consumables 8-15 HRX-OM-X084 Chapter 8 Control, Inspection, Exchange and Cleaning 8.5 Electrical schematic diagram 8.5.1 HRR010-A/W-10Customer power connection port 1-phase HRR010-A/W-10 : AC100V(50/60Hz),115V(60Hz) (CN8) (CN1) 2/2 Blue 2 L N Blue 1B 1 Brown 2B Blue (CN1) AC_CN 1 13 Brown Blue 3B
M1E m x g FE M3E = 1/3 x FE x L2 (FE = 1.4/100 x a x g x m) = 0.05 x a x m x L2 = 0.05 x 300 x 0.5 x 0.04 = 0.3 [Nm] 3B = M3E/M3E max = 0.3/1.07 = 0.28 Investigate M3E. a From above, find the value of M3E max at 420mm/s in Graph 3. M3 M3E m x g FE L2 From above, n = 1 + 2 + 3A + 3B = 0.1 + 0.082 + 0.35 + 0.28 = 0.812.
Micromist separator AMD900, 1000, 901 Model Connect (Flange) 2B 2B/3B/4B 400 A 280 B 6B C 550 D 150 E 270 F 823 G 3 H 797 J 620 AMF801 AMF901 445 12B 570 300 520 1093 3 867 AMF800/900/1000 Mounting Caution q Verify the direction of the flow of the compressed air and the "e" mark that indicates the inlet of the product before connecting.
STO 13.3.2 MR-J3-D05 () 3.2.2 (1) 24 V S4 S2 S1 S3 RESA RESB MR-J3D05 () () SW2 STOA STOB SW1 EM2 EM2 (A ) (B ) CN9 SDI1A+ 1A 1B SDI1AMC SDO1A+ 4A CN8 4B SDO1ACN8A STO1 4 STO2 5 CN10 3A SDI2A+ STOCOM 3 3B SDI2ATOFB1 6 1A SRESA+ 1B SRESATOFB2 7 6A SDO2A+ TOFCOM 8 6B SDO2ACN3 8A TOFA EM2 (A ) M CN9 SDI1B+ 2A 2B SDI1BMC SDO1B+ 3A CN8B CN8 3B SDO1BSTO1 4 STO2 5 CN10 4A SDI2B+ STOCOM 3
ON-flow 0.04 40 B p ipe pe 3/4 B p pi 3B 30 1 0.03 2B, pipe 20 0.02 , 5B , 4B pe 1/4 1 B pi 10 Max.
ON-flow 0.04 40 B p ipe pe 3/4 B p pi 3B 30 1 0.03 2B, pipe 20 0.02 , 5B , 4B pe 1/4 1 B pi 10 Max.
Single solenoid with spacer assembly SY9000-37-3A Double solenoid/3 position with spacer assembly For DC: 9 1 20 02 5 LO SY Z SY9000-37-4A For 100VAC For AC: 1 LOZ SY 9 1 20 02 Specification Single solenoid Double solenoid/ 3 position SY9000 SY9000-37-1B Series SY9000-37-2B 9 SY9000 Single solenoid with spacer assembly SY9000-37-3B Type of actuation Double solenoid/3 position with spacer
2 y r i q 2b 3b CY3RG15 to 63 !9 @2 @0 @3 #0 @5 @8 @7 o u !7 t 18b CY3RG15 CY3RG15, 20 CY3B CY3R CY3B CY3R !9 !8 @2 @1 CY1S CY3RG15 CY1L Switch Rail Accessory CY1H CY1F Switch Rail Accessory Kit B 100 (N) CYR 15 E Bore size (mm) 6 10 15 Kit no. Both sides piping Centralized piping CYR6EBContents CYP Bore size Numbers , , !9, @2, @7 above Numbers , , !
1 Air Tank Series AT Model/Standard Specifications AT11C AT22C AT37C AT55C AT75C AT125C AT150C (1) AT220C (1) AT6C Model Fluid Tank capacity (l) 400 500 700 Compressed air 1000 1500 2000 3000 100 200 Max. operating pressure (MPa) Port size 0.97 Rc 1/2 Rc 3/4 Rc 11/2 2B flange 3B flange 4B flange Set pressure for safety valve (MPa) 0.97 1.46 0 to 100 Proof pressure (Under water pressure) (
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model Flange port size Note) Rated flow rate (L/min) Model/Rated Flow Rate FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA-24 FHIA-28 FHIA-32 1/2B 30 3/4B 50 1B 95 1 1/4B 150 1 1/2B 220 2B 350 2 1/2B 550 3B 770 3 1/2B 1000 4B 1300 The symbol represented by indicates the type of applicable hydraulic fluid.
SY3000-55-2B(-Q) SY5000-55-2B(-Q) SY7000-55-3B(-Q) Applicable series 10-SY3000 Port size 5/16" One-touch fitting 3/8" One-touch fitting 3/8" One-touch fitting Assembly part no. SY3000-54-3C(-Q) SY5000-54-2C(-Q) SY7000-54-3C(-Q) Applicable series 10-SY5000 10-SY3000 10-SY7000 10-SY5000 10-SY7000 [When supplying the manifold with 2 different supply pressures.]
Port size Exhaust cleaner for vacuum pump 10 14 20 30 40 R1 R1 R2 80 (3B) JIS 10K FF flange 1 2 Captures and separates 99.5% of even low-flow and highly concentrated greasy fumes. Using the AMV series, greasy fumes cannot be visibly recognized in the exhaust from the vacuum pump. (When greasy fumes are 1,000 mg/m3 at the IN side, it will be 5 mg/m3 or less at the OUT side.)