SMC Corporation of America
Elite Part Number Search
Search Results "LEFB40US4S-1000-S2"

1 min. between external terminal and case Insulation resistance 50M or more (500 VDC Mega) between external terminal and case 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller. 4.9 m/s2 Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Weight Note 3) 410 g 470 g

/s Piston speed mm/s 4 Series MY2 Maximum Allowable Moment/Maximum Load Weight Moment/MY2H (Single axis) MY2H/M3 MY2H/M1 MY2H/M2 50 60 50 60 50 60 30 30 30 20 20 20 Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 10 10 10 MY2H40 MY2H25 MY2H25 MY2H25 5 5 5 4 4 4 3 3 3 2 2 2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 Piston

For 4 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Positioning/ Pushing Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 100 200.00 1000 1000 0 6.0 12.0 0.5 Axis 2 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 0 Axis 3 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 4 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 1 INC 500 250.00 1000 1000 1 0 0 20.0

Temperature abnormality On 16 Series E-MY2 Auto Switch Specifications Auto Switch Common Specifications Reed switch Solid state switch Type Leakage current 3-wire: 100 A or less 2-wire: 0.8 mA or less None Operating time 1.2 ms 1 ms or less 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 VDC Mega (between lead wire and case) Insulation resistance Withstand voltage 1000 VAC for 1

Series VQ0-1000-2000 Plug Lead Unit: Flip Type Body Ported. Specifications. VQ0-1000-2000 F Kit (D-sub connector) . VQ0-1000-2000 P Kit (Flat ribbon cable connector) . VQ0-1000-2000 T Kit (Terminal block) . VQ0-1000-2000 C Kit (Connector) . VQ0-1000-2000 S Kit (Serial transmission unit) . Series VQ1000 Body Ported Plug Lead Unit: Cassette Type. How to Order Manifold.

MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

Insulation resistance 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller. Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight Note 3) Port size (Rc, NPT, G) 1/8, 1/4 3/8 1/2 Note 1) The system accuracy when combined with PF2A2/3.

REC Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None CX Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CY 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MQQ M 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

CL1 Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MLGC Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CNG 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MNB 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

Acceleration/deceleration time (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) 133 (ms) Speed at a rated motor rotation of 3000rpm Accel/decel time (ms) = {Rated Rotation Speed (r/min) 60 (S) } Screw Lead (mm) 1000 Acceleration/deceleration speed (mm/s2) *Acceleration speed is measured in ms, so this must be calculated as (s) 1000 -54- 5.6.4 Move distance Configuration and Operation

Acceleration/deceleration time (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) 133 (ms) Speed at a rated motor rotation of 3000rpm Accel/decel time (ms) = {Rated Rotation Speed (r/min) 60 (S) } Screw Lead (mm) 1000 * Note) Acceleration/deceleration speed (mm/s2) *Acceleration speed is measured in ms, so this must be calculated as (s) 1000 54 - 5.6.4 Move distance Configuration

R1 R2 SG FG 24 V 0 V S1 S2 SG 24 V 0 V S1 S2 R1 R2 SG FG 24 V 0 V S1 S2 R1 R2 SG FG 24 V 0 V Ground either the reception side or the transmission side of the shielding wire shield.

80 mm/s2 Target position 2: Travel distance 5 mm, Travel speed 20 mm/s, Acceleration 80 mm/s2, Deceleration 80 mm/s2 ii.Calculation example Travel distance [Number of pulses (pulse)] = Travel distance (mm) Encoder resolution (m/pulse) Travel speed [Pulse frequency (pulse/s)] = Travel speed (mm/s) Encoder resolution (m/pulse) Acceleration and Deceleration time [s] =Travel speed (mm/s) /

110 100 120 140 63.5 75.5 88 to 1000 to 1000 to 1000 Front flange type (F) 4FD FY B FT FX (mm) FZ Stroke range Bore size (mm) B FT FD FX FY FZ 40 50 63 74 78 100 9 9 12 12 16 16 80 100 112 58 61 75 100 125 138 to 1000 to 1000 to 1000 Rear flange type (G) 4FD FY B FT FX ZZ + Stroke FZ (mm) Stroke range Bore size (mm) B FT FD FX FY FZ ZZ 40 50 63 74 78 100 9 9 12 12 16 16 80 100 112 58 61

(Error number 5) Blue S1 White Vs Black S2 Set Pressure Range Vs: Power supply 24 VDC 12 to 15 VDC The regulating pressure range, by unit of standard measured pressure, is shown in the table below. One of the preset pressures P1 through P4 is selected by the ON/OFF combination of S1 and S2.

Acceleration/deceleration time (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) 133 (ms) Speed at a rated motor rotation of 3000rpm Accel/decel time (ms) = {Rated Rotation Speed (r/min) 60 (S) } Screw Lead (mm) 1000 Acceleration/deceleration speed (mm/s2) *Acceleration speed is measured in ms, so this must be calculated as (s) 1000 -49- 5.6.4 Move distance Configuration and Operation

CU Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None CQS Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CQM 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) CQ2 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

CJP Type Solid state switch Reed switch Leakage current 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) None CJ2 Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CM2 Insulation resistance 50 M or more at 500 M VDC (Between lead wire and case) Note 3) CG1 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and

Bore size Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm Series CS1 Pressure 0.5 MPa Load factor 50% Cylinder stroke 1000 mm 40 50 63 80 100 125 140 160 180 200 Average speed (mm/s) System VK 1000 Perpendicular, upward actuation Horizontal actuation 900 800 700 600 500 400 300 200 100 VZ A VF VFR 0 1000 VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,