S1 S2 S1 S2 S1 S2 S1 Master unit V BDH SD FG SD FG SD FG SD FG CANL Twisted pair wire with shield FG BDL Class 3 ground Class 3 ground Class 3 ground Class 3 ground CANH V+ Connect the shielding wire to the SD terminal.
Maximum acceleration: 2000mm/s2 Positioning distance (mm) 1200 600 100 10 1 120.5 60.5 10.5 1.5 0.5 10 Speed (mm/s) 12.5 6.5 1.5 0.6 0.5 100 5.4 3.0 1.0 0.6 0.5 250 3.1 1.9 0.9 0.6 0.5 500 A B C D Values will vary slightly depending on the operating conditions. 157 12 Series LG1H21 Standard Motor High Rigidity Direct Acting Guide With Coupling Motor Output Ground Ball Screw 100W 15mm /10mm
1400 1600 0 200 400 600 800 1000 1200 1400 1600 0 0 0 0 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance [mm] Installation distance [mm] Installation distance [mm] Installation distance [mm] IZF10R 25 IZF10R IZF10R
ON/OFF / / 2 3 3 2 1 2 / -20- 3.3. [] LEC LEC / P.32 5.3 <> NPNPNP LEFS16A-100 NPN <> INPIN []INP ON ON INP ON OFF -21- <> No.1 01 a b c d e f g h i j k a ABSINC No. 1 2 mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 ABS 250 50.00 3000 3000 0 0 0 100 48.00 50.00 0.50 1 ABS 250 0.00 3000 3000 0 0 0 100 0.00 2.00 0.50 ABS()/ / INC()// b c d e f 00 g h i 100%DC24V 250% j 12
V: Power supply voltage Power consumption P: 1000 [W] Q = P = 1000 [W] P Cooling capacity = Considering a safety factor of 20%, Power consumption 1000 [W] x 1.2 = 1200 [W] e Derive the heat generation amount from the output. w Derive the heat generation amount from the power supply output. Output (shaft power, etc.)
0 200 400 600 800 1000 1200 1400 VQ4l5l (Plug lead type) ARBQ4000-00-B-5 B ARBQ4000-00-P-5 P Flow rate [L/min(ANR)] ARBQ4000-00-P (P B) 0.7 Dimensions 0.6 Outlet pressure [MPa] 0.5 0.4 SMC 0.3 0.2 59 50 147 0.1 B 2 SMC 1400 0 0 200 400 600 800 1000 1200 12 1 P 5 3 R2 R1 Flow rate [L/min(ANR)] PE 4 A 55.5 Pressure Characteristics 25 218.5 Conditions Inlet pressure: 0.7 MPa Outlet pressure:
Green LED illuminates Ambient temperature Sensor section: 0 to 150C Amplifier section: 0 to 60C D-M9NJ Impact resistance Sensor section: 1000 m/s2 Amplifier section: 300 m/s2 Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications (Grommet) Auto switch model D-M9NJ D-M9PJ Sheath Outside diameter [mm] 3.4 Insulator Number of cores 3 cores (Brown/Blue/Black) Outside diameter
Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction.
Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
Conversion example for a 8[mm] lead actuator driven at an acceleration of 3000 [mm/sec2] Acceleration/Deceleration time constant (ms) = {3000 (r/min) 60 (S) } 8 (mm) 1000 3000 (mm/s2) Rated Motor Rotation Speed (mm/s) Acceleration time constant/deceleration time constant (ms) = {Rated rotation speed (r/min) 60 (S) } x screw lead (mm) x 1000 Acceleration/deceleration speed (mm/s2) *Note)
Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)
Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)
Mount switches in locations where there is no vibration greater than 98m/s2, or impact greater than 490m/s2. 3. Do not use in an area where surges are generated.
Mount switches in locations where there is no vibration greater than 98 m/s2, or impact greater than 490 m/s2. 3. Do not use in an area where surges are generated.
Note 5) The analog output operates only for real-time flow rate, and does not operate for accumulated flow. 9 Series PF2A For Air Digital Flow Switch Flow Characteristics (Pressure Loss) PF2A703H PF2A706H PF2A712H 20 20 20 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 10 10 10 600 0 2400 4800 7200 9600 12000 150 0 600 1200 1800 2400 3000 300 0 1200 2400 3600 4800 6000 Flow
Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.
Indicator light Electrical entry Lead wire Grommet Oilproof flexible heavy-duty vinyl cord, 2.7 x 3.2, ellipse Switch, 1,000 m/s2 Impact resistance Connector, 300 m/s2 JIS C 4524, JIS C 4525 IEC 947-5-2, NECA 0402 In compliance with IP 67 when coupled 50 M or more (500 VDC Mega) between lead wire and case 1,000 VAC for 1 min.
Insulation resistance 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, whichever is smaller. Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Noise resistance 200 g 240 g Weight Note 3) Port size (Rc, NPT, G) 1/8, 1/4 3/8 1/2 Note 1) The system accuracy when combined with PF2A2/3.
) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1CW25 MY1CW25 (1000) (1000) (1000) (1000) MY1MW20 MY1MW20 30 30 (1000) (900) (1000) (900) (1000) (1000) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 (900) (900) (900) (900) (900) (900) 20 20 1.
Do not drop, bump or apply excessive impacts (300m/s2 or more for reed switches and 1000m/s2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction. 2. Do not carry a cylinder by the auto switch lead wires.