SMC Corporation of America
Elite Part Number Search
Search Results "LEY16EA-100C-R3C917"

H A H D N G, J S Q E P V M Y A H K K A H A H B J V M V M Y D, E N, P B J Fluid(Application) Standard A B C D E F NBR FPM Argon Argon(long life) Ethyl Alcohol Ethylene glycol Ozone(low concentration) Caustic soda B PTFE EPR Brass, Copper FPM EPR FPM NBR FPM EPR PTFE FPM FPM FPM EPR PTFE(FPM) PTFE(FPM) NBR FPM FPM FPM H Air(dry) Gas oil Silicon oil Fuel oil(Up to 60C) Fuel oil(Up to 100C

Min. bending radius (mm) 15 Note 3) 20 35 60 95 100 130 Air, Inert gas: -20 to 200C Water: 0 to 100C (No freezing) Operating temperature Material FEP (Fluorinated Ethylene Propylene Resin) Note 1) When using a fluid in liquid form, the surge pressure must not exceed the maximum operating pressure.

How to Order IL 100 02 Suffix Booster relay Nil Standard Thread type T High temperature (5 to 100C) Nil Rc N NPT* L Low temperature (30 to 60C) F G* * Semi-standard S Copper-free ST Copper-free/ High temperature (5 to 100C) Port size 02 1/4 03 3/8 SL Copper-free/ Low temperature (30 to 60C) Accessories Nil None B With bracket Standard Specifications Flow-rate Characteristics Supply pressure

6283 7069 7854 IN 7147 1429 2144 2859 3574 4288 5003 5718 6432 7147 * Theoretical output [N] = Pressure [MPa] x Piston area [mm2] Weight Single Rod (32 to 100) [kg] Bore size [mm] 32 40 50 63 80 100 Basic weight (at 0 stroke) Basic Lock unit 0.42 0.83 1.15 1.79 2.81 5.44 Cylinder (at 0 stroke) 0.55 0.84 1.41 1.79 3.25 4.61 Total 0.97 1.67 2.56 3.58 6.06 10.1 Calculation example) CP96NL32-100C

The maximum allowable temperature of the inlet air is 100C. If the inlet air exceeds this temperature, select an appropriate water cooled style aftercooler. 7. Prevent fins from becoming clogged. Do not use this aftercooler in an area that has viscous dust (electrostatic paint powder, oily particles, etc.).

(Example) Inlet air temperature: 100C, Ambient temperature: 20C, Amount of air: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAA22-14 Outlet Air Temperature at Above Conditions Use outlet air temperature of 38.5C from outlet air temperature table.

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes

Size: 25, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)

Size: 16, Motor Mounting Position: D (In-line), Lead: A (Size 8: 10mm, Size 16: 12mm, Size 25: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type

Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): C91 (JXC91, EtherNet

Size: 16, Motor Mounting Position: In-line, Lead: Size 8: 10mm, Size 16: 12mm, Size 25: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: Screw Mounting, I/O Cable: -, Communication Plug Connector: -, Option: -

Size: 25, Bearing Type: Sliding Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: with Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 3m, Controller Type for (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length

Size: 25, Motor Mounting Position: In-line, Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: Screw Mounting, I/O Cable: -, Communication Plug Connector: -

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting Position: In-line, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Guide Option: w/o Option, Actuator Cable Type, Length: 3m, Controller: Ether Net/IPâ„¢, Mounting: Screw Mounting, I/O Cable: -, Communication Plug Connector: -

Compatibility is indicated for fluid temperatures specified for the respective products (100C or less). Table symbols : Can be used. : Cannot be used. : Can be used under certain conditions. Please consult us.