one minute between external terminals and case Insulation resistance 2Mh or more (at 500VDC megameter) between external terminals and case Vibration resistance 10 to 500Hz vibration width 1.5mm or 9.8m/s2 to X, Y, Z directions 2 hours for each direction Impact resistance 980 m/s2 X, Y, Z direction, 3 times for each direction Cable Oil-proof chloroethylene cable (3.4, 0.2mm2, 5m) Weight 250g
standard Indication Operation lamp: Green when on + deviation indicator Power Supply Voltage DC12~24V Current Comsumption 30mA Output Type: ISA11 NPN open collector 30V 80mA ISA15 PNP open collector 30V 80mA Operating Temp Range 0~60C / 32~140F (no dew formation) Vibration Resistance 10G Proof Pressure 0.5MPa / 73PSI Proof Noise Direct input 1000Vp-p Pulse duration 1s pulse rise 1ns Weight 250g
Repeatability Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range 0 to 50C 5% F.S. or less 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 160mA or less 170mA or less 290g 150mA or less 250g
150mA or less 1000VAC for 1min. between external terminal block and case 2M (500VDC) between external terminal block and case 1000Vp-p, Pulse width 1s, Rise time 1ns 10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/s in X, Y, Z directions for 2 hours each Vibration resistance Impact resistance Weight Enclosure Piping port size 490m/s in X, Y, Z directions, 3 times each 250g
one minute between external terminals and case Insulation resistance 2Mh or more (at 500VDC megameter) between external terminals and case Vibration resistance 10 to 500Hz vibration width 1.5mm or 9.8m/s2 to X, Y, Z directions 2 hours for each direction Impact resistance 980 m/s2 X, Y, Z direction, 3 times for each direction Cable Oil-proof chloroethylene cable (3.4, 0.2mm2, 5m) Weight 250g
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 7.05479 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 25MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 10.58218 lb
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 80mm, Stroke: 250mm, Rod End Thread: G (Long Male Rod End)
Magnet: None, Mounting: L (Foot), Bore Size: 63mm, Stroke: 250mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 32mm, Stroke: 250mm, Rod End Thread: G (Long Male Rod End)
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: G (Head Flange)
Magnet: Built-in, Mounting: Basic, Bore Size: 80mm, Stroke: 250mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: None, Mounting: Foot, Bore Size: 63mm, Stroke: 250mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Foot, Bore Size: 32mm, Stroke: 250mm, Rod End Thread: Long Male Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 32mm, Stroke: 250mm, Rod End Thread: G (Long Male Rod End)
Magnet: D (Built-in), Mounting: BZ (Boss-cut/Basic), Bore Size: 20mm, Stroke: 250mm, Rod End Thread: G (Long Male Rod End)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 0.7, Specification: Built-in magnet, Support bracket: Without auto switch mounting bracket
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: Head Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length