(Example) Inlet air temperature: 100C, Cooling water temperature: 20C, Cooling water flow: 17 l/min Air flow: 2000 l/min (ANR), Air pressure: 0.7 MPa, Model: HAW22-14 Outlet air temperature at above conditions Use outlet air temperature of 37C from outlet air temperature table. At this time correction factor line becomes A .
How to Order JA 40 F 14-150 X11 Option Mounting style X11 High temperature specifications 5 to 100C Nil F L Basic style Flange style Foot style Applicable cylinder nominal thread size Thread nominal size (Standard) Nominal thread size Applicable bore size (mm) M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M30 x 1.5 M36 x 1.5 3-050 4-070 5-080
How to Order JA 40 F 14-150 X11 Option Mounting style X11 High temperature specifications 5 to 100C Nil F L Basic style Flange style Foot style Applicable cylinder nominal thread size Thread nominal size (Standard) Nominal thread size Applicable bore size (mm) M3 x 0.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M30 x 1.5 M36 x 1.5 3-050 4-070 5-080
How to Order JA 40 F 14-150 Option Mounting type None Nil High temperature specifications 5 to 100C Nil F L Basic type Flange type Foot type Applicable bore size (mm) X11 Symbol Applicable bore size (mm) Model 6 10 15 20 30 40 63 80 100 140 160 6 10 10, 15 20 25, 32 40 50, 63 80 100 125, 140 160 Thread nominal size (Standard) Nominal thread size Applicable cylinder nominal thread size Standard
The packing class has been revised to adopt heat resistant materials for using it at a high temperature of up to 100C.
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length
Size: 16, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for
Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Without auto switch (Without built-in magnet) Remarks Symbol Heater Temperature 16 D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Nil H0 H4 H5 5 to 60C None None With 100C heater With 120C heater Solid state auto switch 5 to 150C Reed auto switch (Not applicable to flange size 16) Note) Size 16 is not
Regulator for Chemical Liquids New New Compatible with acid, alkali and DI water Fluid temperature MAX.212F (100c) Set pressure range 2.9 to 58 psi (0.02 to 0.4 MPa) Material Body New PFA Diaphragm PTFE Housing/End plate PVDF No-slide diaphragm eliminates particle generation. Integral fittings type/ tube extensions type are available.
How to Order IL 02 201 Action Suffix 201 Single acting 211 Double acting 220 3 Port Accessories Nil Standard T High temperature (5 to 100C) L Low temperature (30 to 60C) S External parts copper-free Nil None B With bracket Thread type Port size ST External parts copper-free/ High temperature (5 to 100C) Nil Rc N NPT* 02 1/4 IP F G* SL External parts copper-free/ Low temperature (30 to 60C
Pressure gauge is shipped together, but not assembled. 811 IR1000/2000/3000 Series How to Order IR 2 0 0 02 0 Precision regulator Thread type Body size Nil N Note 2) Rc NPT Suffix 1 1 2 3 IR1000 series IR2000 series IR3000 series Nil G F For high temp. environments (5 to 100C) For low temp. environments (30 to 60C) T Note 4) Semi-standard Type of setting L Note 5), 6) 0 1 Note 1) Basic