Size: 10, Motor Size: Standard, Lead Screw Type, mm: K (LEP*6: 4; LEP*10: 5), Stroke: 75mm, Motor Cable Mounting Direction: U (Bottom Entry), Actuator Cable Type: S (Standard Cable), Actuator Cable Length, m: 5, Controller Type - LEC, JXC: C61 (JXC61, Parallel PNP, Step Data Input Type), I/O Cable Length for LEC: No Cable, Controller Mounting: 8 (DIN Rail Mounting), Communication Plug Connector

Table Accuracy: Basic Type, Size: 10, Max. Rotation Torque: Basic, LER10: 0.22; LER30: 0.8; LER50: 6.6, Motor Cable Entry: Basic Type, Entry on Right Side, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type - JXC: JXC61, Step Data Input Type, Parallel PNP, Controller Mounting: DIN Rail Mounting, Communication Plug Connector for DeviceNetâ„¢: 1.5

Style: Single Axis Type, Size: 32, Motor Mounting Position: Top Mounting, Stroke: 1300, Motor Option: w/o Option, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: DIN Rail Mounting, Communication Plug Connector or I/O Cable Length for JXC: 1.5m

Series: Ball Screw Drive, Accuracy: Basic Type, Size: 32, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm, Stroke: 300mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: Standard Cable, Actuator Cable Length

Series: Ball Screw Drive, Accuracy: Basic Type, Size: 25, Motor Mounting Position: Left Side Parallel, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32: 8mm, Size 40: 10mm, Stroke: 200mm, Motor Option: w/Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: Housing B, Bottom, Actuator Cable: Standard Cable, Actuator Cable

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: Without

Size: 10, Motor Size: Compact Type, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 75mm, Motor Cable Mounting Direction: Bottom Entry, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 5, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: No Cable, Controller Mounting: DIN Rail Mounting, Communication Plug Connector or I/O Cable

Size: 10, Motor Size: Standard, Lead Screw Type, mm: LEP*6: 4; LEP*10: 5, Stroke: 75mm, Motor Cable Mounting Direction: Bottom Entry, Actuator Cable Type: Standard Cable, Actuator Cable Length, m: 5, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: No Cable, Controller Mounting: DIN Rail Mounting, Communication Plug Connector or I/O Cable Length

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: with Lock, Guide Option: w/o Guide, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type for (LEC, JXC): JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: w/o Option, Guide Option: w/o Guide, Actuator Cable Type: Standard Cable, Actuator Cable Length: 5m, Controller Type for (LEC, JXC): JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length

Series: Belt Drive, Size: 32, Motor: Step Motor (Servo 24 VDC), Lead: T, Stroke: 1500mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: With, Positioning Pin Hole: Housing B (Bottom), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: Without Cable, Controller

Series: Belt Drive, Size: 25, Motor: Step Motor (Servo 24 VDC), Lead: T, Stroke: 500mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: With, Positioning Pin Hole: Housing B (Bottom), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: Without Cable, Controller

Series: Belt Drive, Size: 32, Motor: Step Motor (Servo 24 VDC), Lead: T, Stroke: 1000mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: With, Positioning Pin Hole: Housing B (Bottom), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: Without Cable, Controller

SMCs vertical type LEHZ, 2-finger electric grippers are structured to maintain workpiece gripping force in the event of an emergency stop or restart. An encloder makes it possible to confirm positioning and to output length measurements. The LEHZ series is lightweight, and body sizes 10, 16, 20 and 25 are available with a compact motor size.2-finger type , Manual override adjustment screw

Body Size: 10, Motor Size: L (Compact), Stroke: 4mm, Finger Option: B (Through-hole in Opening/Closing Direction), Motor Cable Entry: Basic, Entry on the Left Side, Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C61 (JXC61, Parallel PNP, Step Data Input Type), I/O Cable Length for LEC: Without Cable, Controller Mounting: 8 (DIN Rail Mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 1 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Screw Clearance Hole, Rear Mount, Body

Cylinder (Tube) Inner Diameter(φ): 3", Stroke(mm): 1 1/2", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.4, Specification: Built-in Magnet, Support bracket: Screw Clearance Hole, Rear Mount, Body