Between external terminals and case 1000V AC 50/60Hz for 1 min.
, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) Outlet voltage Symbol 500 1 500 VA 100 VAC (50 Hz) 100, 110 VAC (60 Hz) 1000 2 1 kVA Singlephase 2000 2 kVA 3 4 9 200 VAC (50 Hz
[mm/s2] The value of 50% or less is the same as duty ratio 50% Duty ratio: 50% 15000 15000 Duty ratio: 50% Duty ratio: 25% 10 10 Duty ratio: 100% 5000 5000 Duty ratio: 100% Duty ratio: 75% Duty ratio: 75% 0 0 0 10 20 30 0 10 20 30 40 Work load [kg] Work load [kg] LEJS40B LEJS63B 20 20 Acceleration/Deceleration [mm/s2] Acceleration/Deceleration [mm/s2] The value of 50% or less is the same
Refer to the cylinder catalog for details. 10 Optimum Actuation Size Chart of Air Cylinder For JSY3000, A, B port: 8 Horizontal Vertical (Upward) Average speed [mm/s] 0 100 200 300 400 500 600 700 800 32 CM2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 300 mm 40 50 63 CA2 series Pressure: 0.5 MPa Load ratio: 50% Stroke: 500 mm 80 100 125 CS1 series Pressure: 0.5 MPa Load ratio: 50% Stroke
100 150 200 250 0 50 100 150 200 250 Supply pressure (kPa) Supply pressure (kPa) Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Detection nozzle: 1.5 0.6 0.4 0.5 mm 0.25 mm 0.5 Detection distance (mm) Detection distance (mm) 0.3 0.4 0.3 0.2 0.15 mm 0.2 0.15 mm 0.1 0.1 0.03 mm 0.01 mm 0 0 0 50 100 150 200 250 0 50 100 150 200 250 Supply
Specifications ISA2-G1 ISA2-G5 ISA2-H1 ISA2-H5 Model Detection distance Fluid Operating pressure range Recommended detection nozzle 0.01 to 0.25 mm 0.03 to 0.50 mm Dry air (filtered to 5 m) 30 to 200 kPa 1.5 5 or less 8 or less 12 or less 50 to 200 kPa 2.0 10 or less 15 or less 22 or less 50 kPa 100 kPa 200 kPa Supply pressure Consumption flow rate L/min (ANR) 12 to 24 VDC 10%, Ripple (p-p
P1 LED lever meter Sensor S1 S3 Red is on: Output OFF Green is on: Output ON S4 S2 + P2 Red 1 Gap too big S1, S2: Fixed orifice S3: Variable orifice (Set via adjustment knob) S4: Detection nozzle Red 2 Green 1 BEST POSITION The bridge circuit is constructed as shown in the diagram. Position the work piece in front of the nozzle (S4).
Detection nozzle: 1.5 Detection nozzle piping: F type 4 x 2.5 tube 1 m, 3 m, 5 m/G, H type 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa Test conditions ISA3-F ISA3-G 300 60 3 m 1 m 250 50 5 m 1 m 5 m Displayed value Displayed value 200 40 3 m 150 30 100 20 50 10 0 0 0.3 0.25 0.2 0.15 0.1 0.05 0 0.06 0.05 0.04 0.03 0.02 0.01 0 Actual distance [mm] Actual distance [mm] ISA3-H 500 450 3
Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: B (w/Lock), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 200mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m)
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 300mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 200mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication