SMC Corporation of America
Elite Part Number Search
Search Results "LEY32A-500-S5"

3000 400 3000 LEFS32H LEFS32A LEFS32B LEFS40H LEFS40A LEFS40B 2] 2] 2] 2] 2] 2] [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s [mm/s] [mm/s 0 24 200 16 200 8 200 30 200 20 200 10 200 1 30 300 20 300 10 300 40 300 30 300 12 300 2 40 400 30 400 15 400 50 400 40 400 15 400 3 50 500 40 500 20 500 60 500 50 500 20 500 4 60 600 50 600 25 600 80 600 60 600 25 600 5 80 700 60 700

A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo

1. 2. 3. 2 LEY16*A 2,000km LEY25*A 2,500km LEY32A 4,000km LEY16*B 1,000km LEY25*B 1,200km LEY32B 2,000km LEY16*C 500km LEY25*C 600km LEY32C 1,000km a.

Bore stroke 32 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 700 40 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500 800 50 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600 1200 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 450, 500, 600, 700, 800 1400 100 25, 50, 80, 100, 125, 160, 200,

LECSA-S3 63 200 Without lock Nil With lock B LECSB-S5 LECSC-S5 LECSS-S5 40 AC servo motor (absolute encoder) S6 100 *3 (6) Vacuum port direction Left side Nil LECSB-S7 LECSC-S7 LECSS-S7 AC servo motor (absolute encoder) S7 Right side R 63 200 Both side D *1 Fo r mo tor type S 2 and S6, note that the com patible driv er part number suffix is S1, S5. *3When v acuum ov er 50L/m in( ANR), select

, 125, 160, 200, 250, 320, 400, 500, 600 63 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 80 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 Intermediate strokes are available.

40 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 100 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 Intermediate strokes are available.

25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 2000 2000 2000 2000 2000 2000 2000 Minimum Stroke for Auto Switch Mounting 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Refer to Minimum Stroke

40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600

40 800 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Refer to page 6-13-20 for Minimum Stroke for Auto Switch Mounting. 50 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600

, 200, 300 40 100, 200, 300, 500 50 200, 300, 500 63 200, 300, 500 Courtesy of Steven Engineering, Inc. !

A I L A B I L I T Y 12 25, 50, 100 20 25, 50, 100, 200 32 50, 100, 200, 300 40 100, 200, 300, 500 50 200, 300, 500 63 200, 300, 500 Courtesy of Steven Engineering, Inc. !

(Locking type is for VZ300/500 only.) Coil DC V100 Non-locking push type must be pressed in the direction of the arrow.

Note 2) Conversion Cv Flow rate characteristics Max. operating pressure differential Min. operating pressure differential Note 1) (MPa) Port size Body material Orifice diameter (mm) Model Max. system pressure (MPa) Weight (g) AC DC Kv 500 500 500 740 740 860 1390 5430 6840 8440 1.9 2.4 2.4 4.5 5.5 9.5 13 23 31 49 1.6 2.0 2.0 3.9 4.6 8.2 11.0 19.6 26.4 42.8 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/8

MM I Bore 81ze (mm) 40 BQ DC eO eE F GA GB GC GO GL GR J K LV -500 20 500 27 30 70 60 96 Yo %, 44 16 32 10 85 15 26 54 10 10 M8X l .25 6 76.5 ' 50 63 , 80 , 100 M14X1.5 M1 8 Xl .5 M18X 1.5 M22 X l.5 M26Xl .5 -'00 20-600 32 35 81 70 108 y.

(Example) CS2L160-500 28 to 30 160 I 3/4 BaSIC weight . 12.45 (kg) Additional weight .. .. 2 23 (kg!1 00 mm) Cylmder stroke .. 500 (mm) 3.

Electric silICOn rubber(8lack with -MIne two marKs) Hardness NBR (500) , Silicon rubber (40") , Urethane rubber-Fluorine rubber{60-) Electric NBR (50') , Electric silicon rubber(500) How To Order 1 ~ _ _ -.J Pad dla/mm) 02 12 Mounting thread (Application: Refef to List.)

For example, SMC's S-phase LX actuator motors are divided into 500 steps. Thus, one pulse in full step mode equals (360'+ 500=) 0.72'of shaft rotation. See also Stepping. Full Step A half step is the unit of incremental motion that is 1/2 the basic motion step. SMC's 2-phase LX actuator motors are divided into 200 steps. Each pulse in half step mode equals 0.9'of rotation.

VX2 24 VDC GDM2A-G-S5 100 VAC VXK 110 VAC 200 VAC VXD None 220 VAC GDM2A-R 230 VAC VXZ 240 VAC 24 VAC VXS VXS 48 VAC 24 VDC GDM2A-G-Z5 100 VAC GDM2A-R-L1 110 VAC GDM2A-R-L1 200 VAC GDM2A-R-L2 220 VAC GDM2A-R-L2 230 VAC GDM2A-R-L2 240 VAC GDM2A-R-L2 24 VAC GDM2A-R-L5 48 VAC GDM2A-R-L5 VXB VXE With light VXP VXR VXH VXF Gasket Part No. for DIN Connector VCW20-1-29-1-F VX3 VXA Bracket Assembly

For single axis Actuator cable type/length Nil Without cable S1 Standard cable 1.5 m S3 Standard cable 3 m S5 Standard cable 5 m R1 Robotic cable 1.5 m R3 Robotic cable 3 m R5 Robotic cable 5 m R8 Robotic cable 8 m*1 Option Caution Nil Without option S With straight type DeviceNet communication plug for JXCD1 T With T-branch type DeviceNet communication plug for JXCD1 [CE-compliant products