Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): LECPA, Pulse Input Type, NPN, I/O Cable Length for LEC: 1.5m, Controller Mounting: DIN Rail Mounting, Communication Plug
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): JXC51, Parallel NPN, Step Data Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 3m, Controller Type (LEC, JXC): C61 (JXC61, Parallel PNP, Step Data Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 7 (Screw
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 500mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 5m, Controller Type (LEC, JXC): C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length for LEC: w/o Cable, Controller Mounting: 8 (Rail Mounting
EX245-DX1 2Byte Table 11-3 X0 X1 X2 X3 X4 X5 X6 X7 2 Bit 1 Bit 3 Bit 5 Bit 7 Bit 9 Bit 11 Bit 13 Bit 15 4 Bit 0 Bit 2 Bit 4 Bit 6 Bit 8 Bit 10 Bit 12 Bit 14 72 No.EX##-OMY0006CN 11.5. LED EX245-DX1 LED 0 15 OFF ON Fig. 11-2 EX245-DX1 LED 73 No.EX##-OMY0006CN 11.6.
Y7BA is applicable to "-X5" oil proof type (p.2.2-6). 2.2-1 Wide Opening Air Gripper Series MHL2 Specifications 10 16 20 25 32 40 Bore size (mm) One unit can handle workpieces with various diameters Fluid Air Double acting Action A large amount of gripping force is provided through the use of a double piston mechanism, while maintaining a compact design 0.1 to 0.6 0.15 to 0.6 Operating pressure
Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.
MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.
The X5 option, available for the LEY series in sizes 25 and 32, is a dust and drip proof specification equivalent to IP65. The AC servo motors do not require enclosures, but the scraper and lube-retainer configurations are included. Additionally, the body extrusion includes a vent hole and fitting to balance internal pressure so that dust and water are not drawn in.
The X5 option, available for the LEY series in sizes 25 and 32, is a dust and drip proof specification equivalent to IP65. The AC servo motors do not require enclosures, but the scraper and lube-retainer configurations are included. Additionally, the body extrusion includes a vent hole and fitting to balance internal pressure so that dust and water are not drawn in.
Cooling Capacity: 005 (500 W), Communication: B (RS-232C), Tube Size: 19 (3/4"x5/8")
Cooling Capacity: 005 (500 W), Communication: A (RS-485), Tube Size: 19 (3/4"x5/8")
Cooling Capacity: 500 W, Communication: RS-232C, Tube Size: 3/4"x5/8"
Cooling Capacity: 500 W, Communication: RS-485, Tube Size: 3/4"x5/8"
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: NPN, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32B-150, I/O cable length / communication plug(m): 3, Controller/driver mounting method: DIN rail mounting type
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32B-450, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: DIN rail mounting type
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 500mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 1P (LECP1, PNP, Programless Type), I/O Cable
Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 500mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC: 3m
LEH LEY -X5 Bottom mounting (Body tapped) Axial mounting Rod type only (Body tapped) 11LEFS 11LEJS 25ALEC LEC S LEC SS-T LEC Y Motor Cable Entry Direction Motorless Can be selected from 4 directions.