Magnet: D (Built-in), Mounting: B (Basic Style), Bore Size: 32mm, Port Thread: Rc, Stroke: 125mm, Rod Boot: None, Lock Style: HL (With Rear End Lock Locking Style)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Magnet: Built-in, Mounting: Basic Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 125mm, Rod Boot: None, Lock Style: With Rear End Lock Locking Style, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 100mm, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: A53--Reed, DC Volt >5<24, LED, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 150mm, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: F59--Solid State, Gen. Purpose, 3 Wire NPN, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: D (Built-in), Mounting: B (Basic Style), Bore Size: 32mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: None, Lock Style: RN (Rod Side Lock/Non-locking), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread type: Rc,
Magnet: Built-in, Mounting: Basic Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Basic Style, Bore Size: 32mm, Port Thread: Rc, Stroke: 125mm, Rod Boot: None, Lock Style: With Rear End Lock Non-locking Style, Auto Switch: A53--Reed, DC Volt >5<24, LED, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.
To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.
-c" urrent -;:--nge O I-road c t + ---_ In _t _ e_ rn _a _l _v _ o _ lt _ a ,, 9 ,, e_d _'_ 0 cP _ _ + _ ~ 0 I 2AVOf~ __ -Leak current 0 Response time 1.2 ms COJPB6-1OD _ In _d _ ic c.a :.. t_ o_ , _ Ia _ m ..: p _ _ + __ .---!'
Please contact us for the latest version.sales@ocaire.com, MFLD, W/CONNECTOR VFR4000, VALVE, VV*FR* MANIFOLD VFR SERIES, RN, VV*FR* BASE MT 1/2, 5.51155 lb
To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.
MFLD, W/CONNECTOR, VFS4000, VALVE, VV*FS* MANIFOLD VFS SERIES, RN, VV*FS* BASE MT 1/2, 11.6621 lb
Please contact us for the latest version.sales@ocaire.com, MFLD, W/CONNECTOR NVFR4000, VALVE, VV*FR* MANIFOLD VFR SERIES, RN, VV*FR* BASE MT 1/2, .00000 lb
-_'_fJ EI I n V i I m-] lh-rn-ru | 'rl-| #--.lf7l,{! 'rll-r-1 q-___l__rL iJrql_:^-f^/rF+l -Ti-e),ri-?-'J I u c o u p n s / / p e a f l n s Con lnc I F'rolection Box Conlact Protection,,/lnternal Circuit O-R7 and D-Rg type switches have no built-in contact omtection circuit. Use this box for induction loads, 1.5 ft (0.5m) or more of lead wire, or AC 100V aoolications. 9q-q1!