Bearing Type: Slide bearing, Bore Size: 25mm, Port Thread Type: NPT, Cylinder Stroke: 25mm, Auto Switch: M9PWV--Solid State, 2-color Indication, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
Bearing Type: Slide bearing, Bore Size: 25mm, Port Thread Type: NPT, Cylinder Stroke: 75mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 1m, Number: -
The MGP is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing length, thus enhancing the cylinders load bearing capacity. Conventional designed guided cylinders have a set bearing length resulting
dual 3-port valve Operating pressure range Internal pilot operating pressure range (MPa) 0.1 to 0.7 (High pressure type: 0.1 to 1) 100 kPa to 0.7 (4-position: 100 kPa to 0.6) 100 kPa to 0.7 (High pressure type: 100 kPa to 1) 2-position single 2-position double 3-position External pilot operating pressure range (MPa) Pilot pressure range 0.25 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to
100 160 Switch Heater Indicator High-temperature type XLA-100/160-X152 Single acting (N.C.) 106 to atmospheric pressure 1010 1011 XLC-100/160-1-X152 Double acting 1 When the standard seal material (FKM) is used XLA/C-100/160(-1)-X152 18-E692 Aluminum High Vacuum Angle Valve Normally Closed, Bellows Seal XLA-100/160-X152 How to Order XLA 100 w e r q X152 A M9N u t y Improved durability of
100 Gripping point L (mm) Gripping point L (mm) Misc.
Note 2) For other rated voltages (48, 100 VDC), please consult with SMC.
) Backup plate Special resin Guide roller B Special resin Guide roller A Stainless steel (80, 100) MX #6 Special resin (63 to 100) #7 #8 #9 MTS End cover Nickel plated (80, 100) y Carbon steel (80, 100) (80, 100) Wear ring Special resin u i o !
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
40)1 (40)1 (40)1 (100)1 0.5 89 W W W Rod (side) 10.0 (40)1 (40)1 (40)1 0.7 36 74 93 (40)1 0.3 33 37 26 54 69 Head ( side ) 0.5 39 25 27 19 41 52 C8525 C8520 0.7 32 20 22 15 33 43 1.0 Foot: M Rod flange: G Head flange: G (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.3 G G (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.5 W W Rod (side) W (40)1 (40)1 (40)1 (40)1 (100)1 (100)1 0.7 (40)1 (40)1 (40)1 (100)1
Caution 5 150 100 200 300 1.
Operating range and hysteresis How to change the auto switch detecting position Auto switch mounting Auto switch adjustment D53 CRB2 Series Volume [cm3] Vane type Single vane Double vane Size 10 15 20 30 40 10 15 20 30 40 Rotating angle 90 180 270 90 180 270 90 180 270 90 180 270 90 180 270 90 100 90 100 90 100 90 100 90 100 Volume 1 (0.6) 1.2 1.5 1.5 (1.0) 2.9 3.7 4.8 (3.6) 6.1 7.9 11.3
80 100 Applicable pin O.D.
Yes 5 V A93V A93 Grommet 12 V 100 V Relay PLC 24 V 2-wire IC circuit A90V A90 5 V,12 V 100 V or less M9NV M9N 3-wire (NPN) IC circuit 5 V 12 V M9PV M9P 3-wire (PNP) M9BV M9B 12 V 2-wire Relay PLC Yes Grommet 24 V F9NWV F9NW 3-wire (NPN) Diagnostic indication 2-color display IC circuit 5 V 12 V F9PWV F9PW 3-wire (PNP) F9BWV F9BW 2-wire 12 V . . .
(1") 125 (1-1/4") to 200 (2") 012 (1/8") to 100 (1") 125 (1-1/4") to 200 (2") 012 (1/8") to 100 (1") 125 (1-1/4") to 200 (2") 012 (1/8") to 100 (1") 125 (1-1/4") to 200 (2") 012 (1/8") to 100 (1") 125 (1-1/4") to 200 (2") 012 (1/8") to 100 (1") 125 (1-1/4") to 200 (2") 0.76 0.67 1.42 1.33 2.50 2.47 056 (9/16") 3.06 075 (3/4") 3.42 106 (1-1/16") 3.73 Single Acting, Spring Extend Unit: lbs
, 125, 150 25 25, 50, 75, 100, 125, 150 32 25, 50, 75, 100, 125, 150, 200 40 25, 50, 75, 100, 125, 150, 200, 250 Note 1) Other intermediate strokes can be manufactured upon receipt of order.
Model XL-25-2 XL-40-2 XL-50-2 XL-63-2 XL-80-2 Rated voltage for heater 90 to 240 VAC Heater assembly quantity 1 1 1 1 H4 100C 100 V 200/40 200/50 400/100 600/150 Heater assembly quantity used Heater power W (Nominal value) Inrush/Power consumption (Option symbol, Operating voltage) 200 V 800/40 800/50 1600/100 2400/150 Heater assembly quantity 1 1 1 1 2 H5 120C 100 V 200/40 400/70 400/
(25 to 40) 2001 to 5000 (50, 63) 25, 32, 40, 50, 63 100 to 1000 10 to 100 20, 25, 32 10 15 20 25 100 to 300 100 to 500 100 to 600 100 to 800 301 to 500 501 to 750 601 to 1000 801 to 1200 10, 20, 30, 40, 50 75, 100, 125, 150 10, 15 CY1H CXSW 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 20, 25, 32 ML1 25 32 1001 to 1200 1001 to 1500 25, 32, 40 100 to 1000 1001 to 2000 2001 to 4000 (25, 32
9 9 80 92 108 75, 100 74 56 M FV 80 10 to 50 73.5 53.5 83.5 63.5 11 11 99 116 134 75, 100 83.5 63.5 100 10 to 50 85 63 95 73 11 11 117 136 154 75, 100 95 73 FT L B + Stroke A + Stroke 4 x FD FX FZ Bore size (mm) Stroke range (mm) L L1 M 63 10 to 50 18 43.5 60 75, 100 80 10 to 50 20 53.5 77 75, 100 100 10 to 50 22 53.5 94 75, 100 L1 Flange bracket material: Carbon steel Surface treatment: