Model Bore size (mm) Gripping moment (Nm) (Effective value) (1) Opening/closing angle (Both sides) Weight (2) (g) Action Model MHC2-10D MHC2-16D MHC2-20D MHC2-25D 39 91 180 311 0.10 0.39 0.70 1.36 10 16 20 25 30 to 10 Double acting MHC2-10S MHC2-16S MHC2-20S MHC2-25S 0.070 0.31 0.54 1.08 39 92 183 316 10 16 20 25 MHC2-16S 30 to 10 Single acting Note 1) At the pressure of 0.5 MPa.
Model Bore size mm Holding moment (effective value) (1) Opening/closing angle (both sides) Weight (2) Action Model g 39 91 180 311 10 16 20 25 0.10 0.39 0.70 1.36 MHC2-10D MHC2-16D MHC2-20D MHC2-25D 30 to 10 Double acting 0.070 0.31 0.54 1.08 10 16 20 25 39 92 183 316 MHC2-10S MHC2-16S MHC2-20S MHC2-25S MHC2-16S 30 to 10 Single acting MHC2-10D Note1) At pressure 0.5MPa.
DMHZ2-40S 350 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 40 20300 0.6 MPa 0.6 MPa 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 250 30 0.5 MPa 0.5 MPa 0.5 MPa 0.5 MPa 200 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa 20 150 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MPa 100 10 0.25 MPa 0.25 MPa 50 0 10 20 30 40 50 60 0 50 100 150 200 Gripping point L (mm) Gripping point L (mm) MHZ2-20S
DMHZ2-40S 350 Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa Pressure 0.7 MPa 40 20300 0.6 MPa 0.6 MPa 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 250 30 0.5 MPa 0.5 MPa 0.5 MPa 0.5 MPa 200 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa 20 150 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MPa 100 10 0.25 MPa 0.25 MPa 50 0 10 20 30 40 50 60 0 50 100 150 200 Gripping point L (mm) Gripping point L (mm) MHZ2-20S
MHKL2-20S MHKL2-20C D80 60 70 2050 Gripping force (N) Gripping force (N) 60 50 40 Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 40 30 Model Allowable moment Allowable Moment 0.5 MPa 0.5 MPa 30 0.4 MPa 20 0.4 MPa 20 0.3 MPa (Nm) 0.3 MPa 10 10 MHKL2-12S/C 0.05 0 0 MHKL2-16S/C 0.12 20 40 60 80 20 40 60 80 MHKL2-20S/C 0.25 Gripping point L (mm) Gripping point L (mm) MHKL2
MHKL2-20S MHKL2-20C D80 60 70 2050 Gripping force (N) Gripping force (N) 60 50 40 Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa Pressure 0.6 MPa 40 30 Model Allowable moment Allowable Moment 0.5 MPa 0.5 MPa 30 0.4 MPa 20 0.4 MPa 20 0.3 MPa (Nm) 0.3 MPa 10 10 MHKL2-12S/C 0.05 0 0 MHKL2-16S/C 0.12 20 40 60 80 20 40 60 80 MHKL2-20S/C 0.25 Gripping point L (mm) Gripping point L (mm) MHKL2
Mounting bolt Mounting bolt Spring Return Spring Extend D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 Model C Mounting bolt Model C Mounting bolt CQ2B12-5S -10S CQ2B16-5S -10S CQ2B20-5S -10S CQ2B25-5S -10S CQ2B32-5S -10S CQ2B40-5S -10S CQ2B50-10S -20S CQ2B12-5T -10T CQ2B16-5T -10T CQ2B20-5T -10T CQ2B25-5T -10T CQ2B32-5T -10T CQ2B40-5T -10T CQ2B50-
Model C Mounting bolt Model C Mounting bolt D 35 40 40 45 40 45 40 45 40 45 45 50 55 65 D 40 45 40 45 40 45 40 45 40 45 45 50 55 65 CDQ2B12-5S -10S CDQ2B16-5S -10S CDQ2B20-5S -10S CDQ2B25-5S -10S CDQ2B32-5S -10S CDQ2B40-5S -10S CDQ2B50-10S -20S CDQ2B12-5T -10T CDQ2B16-5T -10T CDQ2B20-5T -10T CDQ2B25-5T -10T CDQ2B32-5T -10T CDQ2B40-5T -10T CDQ2B50-10T -20T M3 X 35 l X 40 l M3 X 40 l X 45 l
Mounting bolt Mounting bolt Spring Return Spring Extend Model C Mounting bolt Model C Mounting bolt D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 D 25 30 25 30 25 30 30 35 30 35 35 40 45 55 CQ2B12-5S -10S CQ2B16-5S -10S CQ2B20-5S -10S CQ2B25-5S -10S CQ2B32-5S -10S CQ2B40-5S -10S CQ2B50-10S -20S CQ2B12-5T -10T CQ2B16-5T -10T CQ2B20-5T -10T CQ2B25-5T -10T CQ2B32-5T -10T CQ2B40-5T -10T CQ2B50-
holding:3.4 (15) I.D. holding :3.6 (16) 4 9 13 2.6 O.D. holding:7.0 (31) I.D. holding :8.1 (36) MHK2-16D 16 6 14.6 20.6 4.0 Double acting O.D. holding:10.3 (46) I.D.holding :12.6 (56) MHK2-20D 20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S
If it is a shorter operating time, there is a possibility of accidental breaker trip due to the internal motors inrush currents of this product. 4h 2h 4h 1h 2h 30min 20min 14min 10min 1h 10min 14min 20min 30min 6min 4min 4min 6min 2min 2min 1min Max. 1min 30s 20s Operating time 20s 30s Operating time 10s 10s 5s 5s Min.
Note 2) Weight g Gripping force per finger Effective value N Action Internal gripping force External gripping force 4 55 9.8 10 MHZ2-10D (N) 17 Double acting Single acting 6 115 30 16 40 MHZ2-16D (N) 10 235 42 20 66 MHZ2-20D (N) Single acting type, normally open 14 430 65 25 104 MHZ2-25D (N) 4 55 6.3 10 MHZ2-10S (N) Normally closed Normally open 6 115 24 16 MHZ2-16S (N) 10 240 28 20 MHZ2-20S
II Rod packing NSR I 50 63 MOH-20 DRP-20S NLP-50 NLP-63 @I Piston packing NBR NLP-40 fD Tube gasket NSR CM-040-16-127 Il!
AL-20S FGFL1 1 5 Note) Refer to How to Order on page 267 for the part of the model number.
AL-20S FGFL1 1 5 Note) Refer to How to Order on page 267 for the part of the model number.
Series MHC2/MHCA2/MHCM2 Series MHC2 MHCA2/MHCM2 Series MHC2 MHC2 MHC2 MHC2 2 MHCA2 M MHCA2 MHCA2 MHCA2 M M /MHCM2 MHC2-6 Body option (Only for MHCA2-6) Auto switch is attachable. 48mm x 20mm x 10mm 22g Port Side piping (Full size) MHCA2-6 With 4 one-touch fitting Short body. 41mm x 20mm x g 10mm 19g Port With 4 hose nipple (Full size) MHCM2-7S Smallest size and lightest weight in MHC series
MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ Auto switch 2.3-4 Series MHR2/MDHR2 Holding Point Limitation of holding point: External hold/Internal hold Proper holding points should be selected in accordance with the operating pressure. The distance to the holding point L and the overhang distance H should be within the limit range shown in the graph on the right.
Dust proof construction MHS MHC2 Bearings are standard.
Light illuminating position MHC2 MHT2 MHY2 Step 5) Move the auto switch in the opposite direction 0.3 to 0.5mm in the direction indicated by the arrow from its location when the indicator light comes on again.
MHC2 Symbol MHT2 MHY2 MHW2 MRHQ Caution Auto switch Be sure to read before handling. Refer to p.0-20 and 0-21 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.2.0-3 and 2.0-4 for precautions on every series.