{21} MHY2-20D M5x0.8 4.3{44} MHY2-25D M6x1 7.3{74} 1. 2. 1. 2. 9 3. 3. 4.
(PAT.PEND) Over length L(mm) Gripping moment Weight (g) Bore size (mm) Model (Nm) L MHW2-20D 68 300 20 0.30 MHW2-25D 510 25 0.73 78 905 MHW2-32D 32 93.5 1.61 2135 MHW2-40D 117.5 40 3.70 5100 Auto switch mounting at 4 locations MHW2-50D 154 50 8.27 At the pressure of 0.5 MPa MHZ Two finger types available.
(Nm) L(mm) MHM-16D M6x1 5.2 11.5 MHM-25D M8x1.25 12.5 12.4 MHM-32D M10x1.5 24.5 13.5 MHM-50D M12x1.75 42 16 3.
Example) -M9NL Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
, 12 V A93 A90 M9N M9P M9B F9NW F9PW F9BW A93V A90V M9NV M9PV M9BV F9NWV F9PWV F9BWV 2-wire Relay, PLC IC circuit 100 V or less No 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Grommet Relay, PLC Yes 24V 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL
Solid state switch Yes Yes Grommet Relay, PLC A93 A93V 2-wire 12 V 24 V 100 V M9N M9NV 3-wire (NPN) IC circuit 5 V, 12 V M9P M9PV 3-wire (PNP) Relay, PLC M9B M9BV 2-wire 12 V 24 V Grommet F9NW F9NWV 3-wire (NPN) 5 V, 12 V Diagnostic indication (2-color indication) F9PW F9PWV 3-wire (PNP) F9BW F9BWV 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL
Lead wire length symbols:0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 12-13-25 for solid state switch with pre-wire connector. 12-5-4 5 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 30 Model/Specifications Nominal size 10 15 20 Action Double acting Gripping force (N) (1) External grip 12 24 33 58 (Effective value) at 0.5 MPa Internal grip 12 34
CQSXB00-20D CQSXB00-45D x 65 L x 40 L 65 40 CQSXB00-25D CQSXB00-50D x 70 L x 45 L 70 45 CQSXB00-30D CQSXB25-5D CQ-M5 x 30 L x 50 L 30 50 Mounting bolt CQSXB16-5D CQSXB00-10D x 35 L CQ-M3 x 25 L 35 25 CQSXB00-10D CQSXB00-15D x 40 L x 30 L 40 30 CQSXB00-15D CQSXB00-20D x 45 L x 35 L 45 35 6.5 CQSXB00-20D CQSXB00-25D x 50 L x 40 L 50 40 8.5 CQSXB00-25D CQSXB00-30D x 55 L x 45 L 55 45 CQSXB00
M8X1.25 12 7 MHL2-25D M8X1.25 17.7 16 MHL2-32D M8X1.25 12 11 MHL2-32D M8X1.25 18 16 MHL2-40D M0X1.5 24 12 MHL2-40D M10X1.5 36 20 Nm MHL2-10D M4X0.7 2.1 MHL2-16D M5X0.8 4.3 MHL2-20D M6X1 7.3 MHL2-25D M8X1.25 17.7 6 - 1. 2. 2 <> AS1200-M5AS2200-01 AS1000AS2000 AS1001FAS2051F 7 - 3-5 Nm MHL2-10D M4X0.7 1.4 MHL2-16D M5X0.8 2.8 MHL2-20D M6X1 4.8 MHL2-25D M8X1.25 12.0 MHL2-32D M10X1.5 24.0
MHK2-25D MHKL2-16D MHKL2-20D MHKL2-25D MHKL2-20D 60 Pressure 0.6MPa Holding force N 50 0.5MPa 41 40 0.4MPa Guidelines on model selection according to work weight Although the condition differs according to the friction coefficient between the attachment and work, select a model that can produce a holding force 10 to 20 times the work weight.
5 6.5 5 3 24 5 3 24 6 3 5 4.5 24 4 4 4 33 33 33 (mm) I 4 5 5 Model MHS2-16D MHS2-20D MHS2-25D G 25 27 28 FZ 3 3 5 FY 11 13 14.5 FX 12.5 14.5 17 CB 11 13 15 EC 10 12 14 EO 14 16 20 NB 5h9 6h9 6h9 DC 30 36 42 NA 8 10 12 DO 34 40 48 K 4 5 6 B 30 36 42 Q 6 7 8 J 10 12 14 AA 35 38 40 AB 32 35 37 O 2 2.5 3 P M3 x 0.5 M5 x 0.8 M5 x 0.8 0 -0.030 0 -0.030 0 -0.030 Model MHS2-16D MHS2-20D MHS2-25D
Series MHC2/MHCA2/MHCM2 Series MHC2 MHCA2/MHCM2 Series MHC2 MHC2 MHC2 MHC2 2 MHCA2 M MHCA2 MHCA2 MHCA2 M M /MHCM2 MHC2-6 Body option (Only for MHCA2-6) Auto switch is attachable. 48mm x 20mm x 10mm 22g Port Side piping (Full size) MHCA2-6 With 4 one-touch fitting Short body. 41mm x 20mm x g 10mm 19g Port With 4 hose nipple (Full size) MHCM2-7S Smallest size and lightest weight in MHC series
A C width across flats D Model A B C MHZ2-10D-X46 MHZ2-16D-X46 MHZ2-20D-X46 MHZ2-25D-X46 9 11 4.5 5.2 7.5 13 7 5.8 10 15 7 6 10.7 20 7 6.2 Refer to pages 4 through 7 for the standard type dimensions, which are the same except for those shown above. Reference value to establish criteria for needle adjustment.
15D (M) 20D (M) 20D (M) 25D (M) 25D (M) 30D (M) 30D (M) 7 35D (M) 35D (M) 14.5 40D (M) 40D (M) 45D (M) 45D (M) 50D (M) 50D (M) 75D (M) 75D (M) x 165l 100D (M) 100D (M) M5 x 75l x 80l x 85l CHQB100 10D (M) M10 x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 145l x 170l CH QB40 5D (M) 15D (M) 10D (M) 20D (M) 15D (M) x 90l x 95l x 100l x 105l x 110l x 115l x 120l x 145l x 170l 25D
(M) 20D (M) 30D (M) 25D (M) 10 35D (M) 30D (M) 15.5 40D (M) 35D (M) 45D (M) 40D (M) 50D (M) 45D (M) 75D (M) 50D (M) 100D (M) CHQWB32 5D (M) M10 x 100l x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 165l x 190l M10 x 105l x 110l x 115l x 120l x 125l x 130l x 135l x 140l x 145l x 170l x 195l CHQWB80 10D (M) 10D (M) 15D (M) 15D (M) 20D (M) 20D (M) 25D (M) 25D (M) 30D (M) 30D (M)
Bore Size: 25mm, Action: D (Double Acting)
How Grip: Pinch, Swing Type / Open, Swing Type, Number of Fingers: 2 Pcs., Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Environment, Applications: Standard, Additional Function: Not Provided, Stroke Adjustment Mechanism: Not Provided, Claw Opening Angle A1(deg): 30, Claw Closing Angle A2(deg): 10, Cylinder internal diameter(mm): 25, Auto switch:
MHZJ2 MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ Auto switch 2.3-4 Series MHR2/MDHR2 Holding Point Limitation of holding point: External hold/Internal hold Proper holding points should be selected in accordance with the operating pressure. The distance to the holding point L and the overhang distance H should be within the limit range shown in the graph on the right.
Light illuminating position MHC2 MHT2 MHY2 Step 5) Move the auto switch in the opposite direction 0.3 to 0.5mm in the direction indicated by the arrow from its location when the indicator light comes on again.
As a rule, it should be turned about 90 beyond the point at which tightening can be felt. 0.5 0.2 0.3 MHL2-20D 0.5 0.2 0.2 MHC MHL2-25D 0.2 0.1 0.2 MHL2-32D 0.4 0.4 0.7 MHT MHL2-40D 0.2 0.4 0.7 MHY MHW MRHQ Misc.