Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: L (Low Load Shock Absorber+Adjust Bolt), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: L (Low Load Shock Absorber+Adjust Bolt), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: L (Low Load Shock Absorber+Adjust Bolt), Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: L (Low Load Shock Absorber+Adjust Bolt), Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: L (Low Load Shock Absorber+Adjust Bolt), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Piping: Standard Type, Stroke: 100mm, Stroke Adjustment Unit: Left: w/o Unit; Right: w/o Unit, Option: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: L (3m)

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: Low Load Shock Absorber+Adjust Bolt, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 20mm, Piping: Standard Type, Stroke: 100mm, Stroke Adjustment Unit: Left: w/o Unit; Right: w/o Unit, Option: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 3m, Number: -

Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 20, Stroke(mm): 100, Max. Load Mass (Horizontal Mounting)(kg): 20~39.9, Table Size Length L(mm): 100, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Guideless] Prototype, Table Size Width W(mm): 37, Table Size Height H(mm): 46, Table Surface Treatment: [Anodize] Hard Anodize, Environment

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: Low Load Shock Absorber+Adjust Bolt, Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: Low Load Shock Absorber+Adjust Bolt, Auto Switch: M9NWV--Solid State, 2-color Indication, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: Low Load Shock Absorber+Adjust Bolt, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Then, the charging time (T) for a 100l tank, With the pressure increase ratio from 2 to 3, the time of 17060=110 sec.(t) is given for 10l tank by the graph. Then, the charging time (T) for a 100l tank, With the pressure increase ratio from 1.6 to 2.0, the time of 3.51.1=2.4 sec.(t) is given for 10l tank by the graph.

Use 0.75kW per 100l/min of air consumption as a guide for the relationship of the air consumption to the compressor.

Use 0.75kW per 100l/min of air consumption as a guide for the relationship of the air consumption to the compressor.

Use 0.75kW per 100l/min of air consumption as a guide for the relationship of the air consumption to the compressor.

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: L (Low Load Shock Absorber+Adjust Bolt), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length, M8-3 Pin Connector)

Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 100mm, Stroke Adjusting Unit: Low Load Shock Absorber+Adjust Bolt, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M8-3 Pin Connector, Number: -

Operating range RB Model C 8 8 8 8 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 x 50l M3 x 60l M3 x 50l M3 x 60l M5 x 75l M5 x 85l M5 x 75l M5 x 85l M5 x 85l M5 x 95l M5 x 75l M5 x 85l M6 x 95l M6 x 130l M8 x 100l M8 x 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50

Example) M5 x 75l (MK2B) MK232/40 10 2 ML2B 6 Moment of inertia (kgm2) C J G5-S 4 MK220/25 CV 2 Mounting bolt 10 3 MVGQ 6 CC 4 Flat washer Operating range RB 2 Note) Be sure to use a flat washer to mount cylinders via through-holes. 10 4 J Model C D 75 85 80 90 90 100 80 90 105 135 105 135 Mounting bolt M5 x 75l M5 x 85l M5 X 80l M5 x 90l M5 x 90l M5 x 100l M5 x 80l M5 x 90l M6 x 105l M6