Magnet: None, Mounting: Basic, Bore Size: 2", Stroke A: 18", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 6", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: None, Mounting: Basic, Bore Size: 2", Stroke A: 6", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 16", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
30 s Switching the signal type of the contact input 1 OFF/RN.ST/ RUN/SW/ RN.ST Switching the signal form of the contact input 1 ALT/MT ALT Contact type switching of contact input 1 A/B A Alarm switching for contact input 1 OFF/WRN/FLT OFF Communication Delay time setting for contact input 1 0600 0 s Setting Menu Chapter 5.8 OFF detection time setting for contact input 1 010 0 s Switching
(6") 075 (3/4") 088 (7/8") 106 (1-1/16") 125 (1-1/4") 150 (1-1/2") 200 (2") 0050 (1/2"), 0100 (1"), 0150 (1-1/2"), 0200 (2"), 0250 (2-1/2"), 0300 (3"), 0400 (4"), 0600 (6") Double acting Double rod 075 (3/4") 088 (7/8") 106 (1-1/16") 125 (1-1/4") 150 (1-1/2") 0050 (1/2"), 0100 (1"), 0200 (2"), 0300 (3"), 0400 (4"), 0500 (5") 0600 (6") Single acting Single rod Now available in 8 different
Step Request data Response data Operation details 01 10 0600 000A Alarm history command to clear alarm 14 0 0 0 0 1 01 10 0600 000A history sent. (0 to 10 entries) 0 0 0 0 0 0 01 10 060A 000A Alarm history command to clear alarm 14 0 0 0 2 01 10 060A 000A history sent. (11 to 20 entries) 0 0 0 0 0 0 0 67 - Caution Ensure the alarm history is cleared only after taking corrective action in
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 150 (1 1/2"), Stroke A: 0600 (6"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0600 (6"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: None, Mounting: Basic, Bore Size: 2", Stroke A: 6", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 6", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Series: NCA1 (Standard), Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6")
Series: Standard, Mounting: MX0, Basic, Bore Size: 2", Stroke: 6", Air Cushion / Rod Boot: -, Thread: -, Adjustment Range: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Series: NCA1 (Standard), Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: F (Flanged), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)
Series: NCA1 (Standard), Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: IM (Intermediate Male, Threaded)
Series: NCA1 (Standard), Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: SF (Short Female, Threaded)
Series: NCA1 (Standard), Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs.
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
Series: NCA1, Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Option: Both Ends (Air Cushion), X Option: XB6 [Heat Resistant Cylinder, up to 300°F (150°C)]
Series: NCA1, Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Option: Both Ends (Air Cushion), X Option: XB7 [Cold Resistant Cylinder, down to -22° F (-30° C)]
Magnet: None, Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)
Magnet: None, Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC35 (with Coil Scraper)
Magnet: None, Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC22 (Viton Seals)