Note 5) The analog output operates only for real-time flow rate, and does not operate for accumulated flow. 11 Digital Flow Switch Series PF2A For Air Flow Characteristics (Pressure Loss) PF2A703H PF2A706H PF2A712H 20 20 20 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 10 10 10 600 0 2400 4800 7200 9600 12000 150 0 600 1200 1800 2400 3000 300 0 1200 2400 3600 4800 6000 Flow
4800 7200 9600 12000 0 600 1200 1800 2400 3000 0 1200 2400 3600 4800 6000 Flow [L/min] Flow [L/min] Flow [L/min] 11 3-Color Display Digital Flow Switch for Large Flow PF3A7 H Series IN Side Straight Section and Accuracy (Reference Data) PF3A703H (for 3000 L/min) PF3A706H (for 6000 L/min) PF3A712H (for 12000 L/min) 70% 70% 70% PFG300 Function Details PF3A7 H With 1/2" connected With 1" connected
Note 5) The analog output operates only for real-time flow rate, and does not operate for accumulated flow. 9 Series PF2A For Air Digital Flow Switch Flow Characteristics (Pressure Loss) PF2A703H PF2A706H PF2A712H 20 20 20 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 10 10 10 600 0 2400 4800 7200 9600 12000 150 0 600 1200 1800 2400 3000 300 0 1200 2400 3600 4800 6000 Flow rate
Note 5) The analog output operates only for real-time flow rate, and does not operate for accumulated flow. 16-11-14 11 Series PF2A Digital Flow Switch, High Flow Type For Air Flow Characteristics (Pressure loss) PF2A703H PF2A706H PF2A712H 20 20 20 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 10 10 10 ZSE ISE PSE Z I SE3 600 0 2400 4800 7200 9600 12000 150 0 600 1200 1800 2400
Note 5) The analog output operates only for real-time flow rate, and does not operate for accumulated flow. 16-11-14 11 Series PF2A Digital Flow Switch, High Flow Type For Air Flow Characteristics (Pressure loss) PF2A703H PF2A706H PF2A712H 20 20 20 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 10 10 10 ZSE ISE PSE Z I SE3 600 0 2400 4800 7200 9600 12000 150 0 600 1200 1800 2400
PA06 1 262144 (Position control mode) 2000 1200 600 2400 1600 800 3000 2000 1000 Electronic gear denominator *3.
High inlet pressure Changes from the standard type are: 30 0.21 AP1210 AP1215 Option Other Parameters Vacuum to 3000 psig (20.7 MPa) ) 4500 psig (31 MPa) 9000 psig (62 MPa) HR Source pressure 20 0.14 Proof pressure (Inlet) Burst pressure 10 0.07 ) 3/4 inch face seal fittings rated to 2400 psig (16.5 MPa) maximum.
(Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 1800 (18"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 1800 (18"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0050 (1/2"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
(Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0050 (1/2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1800 (18"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
(Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 250 (2 1/2"), Stroke A: 1800 (18"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0200 (2"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
(Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Initial value (dec) Remarks storage 2 CH1 CH2 CH3 CH4 Set the accumulated direction. 0: Add (Addition) 1: dEC (Subtraction OUT1) 2: dEC2 (Subtraction OUT2) AC (Accumulated display direction) 0x0640 (1600) 0x0641 (1601) 0x0642 (1602) 0x0643 (1603) 0 R/W Y U8 0x0 (0) Setting of digital filter. 0x0 ~ 0x0BB8 (0 ~ 3000) 0.01 s increment 0x070B (1803) 0 R/W FiL (Digital filter) Y U16 0x0 0x0708 (1800
Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards
Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards
Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/300, 1200/500, 1800/500, 2400/700, 3000/700, 5100/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards
Fluid fill, drain port, and filter access on the front; Color LCD screen with control pad for settings and diagnostics; RS-232C / RS-485 Communication functions; Cooling/Heating capacities (W): 1100/200, 1200/500, 1800/500, 2400/700, 3000/700, 5900/1200; Temperature stability: ±0.1°C; Power supply requirement: 200~230 VAC, 50/60Hz; Circulating Fluid: water or 15% ethylene glycol; Standards