SMC Corporation of America
Elite Part Number Search
Search Results "NCDA1B200-0100 2000-XC11"

Magnet: None, Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 1000 (10"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 200 (2"), Stroke A: 0350 (3 1/2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 200 (2"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)

Magnet: None, Mounting: S (Side Lug), Bore Size: 200 (2"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)

D1 20 30 40 50 10 5 -X Transfer speed: (m/min) 20Data Bore Size 32 to 100/MGPM32 to 100 (Slide bearing) MGPM32 to 100 (Slide bearing) m m 2000 l 50 mm l 50 mm 100 1000 80 Weight of transferred object: m (kg) 63 500 400 50 300 40 200 When selecting a model with a longer l dimension, be sure to choose a bore size which is sufficiently large. 32 100 Caution Caution on handling Note 1)

-XC8 to XC11 1 2 Reversed Shaft Change of Rotating Range -XC7 CRB2 CRBU2 CRA1 Refer to How to Order on page 11-7-40. XC8 CRA1 Refer toHow to Order on page 11-7-40.

-XC8 to XC11 1 2 Reversed Shaft Change of Rotating Range -XC7 CRB2 CRBU2 CRA1 Refer to How to Order on page 11-7-40. XC8 CRA1 Refer toHow to Order on page 11-7-40.

-XC11 Dual stroke cylinder/Single rod type -XC12 Tandem cylinder*1 -XC13 Auto switch rail mounting -XC20 Head cover axial port -XC22 Fluororubber seal -XC25 No fixed throttle of connection port*1 Pivot bracket * Pivot bracket is available only for C, T, U, E, V, UZ mounting types. * No bracket is provided for the female rod end.

NPT ports Mounting type MB1 XC11 Bore size Stroke A Suffix Stroke B Suffix Fluoro rubber seals XC22 16 Dual stroke cylinder single rod type Seal material is changed to fluoro rubber for superior chemical resistance.

Ball bushing/MGGLStroke 3000 P = 0.5MPa 2000 MGGL100MGGL801000 MGGL63Allowable eccentric load W (N) MGGL50500 MGGL40MGGL32100 MGGL25MGGL2050 10 0 50 100 150 200 Eccentric distance from center of cylinder to load center of gravity l (mm) (Set the maximum allowable load so that it does not exceed the following percentages of the theoretical output: 40% for 20, 50% for 25, and 60% for 32, 40

Foot, Flange, Single clevis: Mounting bolts Double clevis: Clevis pin, Cotter pin Refer to page 6-6-11 for details. 6-6-5 5 Series MB Allowable Kinetic Energy Theoretical Force (Unit: N) OUT IN 2000 1.0 Rod diameter (mm) Operating direction Piston area (mm2) Operating pressure (MPa) Bore size (mm) 125 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.9 1000 100 804 OUT 643 563 482 402 322 241 161 724 804 32

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

2000 100 100 0 0 3 4000 2000 70 60 500 1 4 500 2000 60 70 1000 1 5 1000 2000 80 80 0 0 6 2000 1000 80 80 0 0 7 1000 1000 80 80 0 0 8 1000 1000 100 100 0 0 LEC-MR-J3BAT 1000 1000 100 100 0 0 C N 4 ( 3 ) 255 2000 2000 80 80 0 0 RS-422 USB CN 6 CN 1 CN3 CN5 DI/O ON USB CC-Link RS-422 1.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB Standard Stroke Maximum stroke (mm) Standard stroke (mm) Note) Bore size (mm) MB1 20 1000 CA2 25 1500 25, 50, 75, 100, 125, 150 200, 250, 300 32 CS1 2000 40 2000 Made to Order Specifications (For details, refer to page 6-17-1.)

Ball Bushing Bearing: MGGLStroke 3000 P = 0.5 MPa 2000 MGGL100MGGL801000 MGGL63MGGL50Allowable eccentric load W (N) 500 MGGL40MGGL32100 MGGL25MGGL2050 10 0 50 100 150 200 Eccentric distance from center of cylinder to load center of gravity (mm) (Set the maximum allowable load so that it does not exceed the following percentages of the theoretical output: 40% for 20, 50% for 25, and 60% for

[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.

Magnet: Built-in, Mounting: Basic, Bore Size: 2", Stroke A: 1", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod