Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.
[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
Magnet: Built-in, Mounting: Basic, Bore Size: 3 1/4", Stroke A: 1", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 2", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 3 1/4", Stroke A: 3", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod
Magnet: Built-in, Mounting: Basic, Bore Size: 3 1/4", Stroke A: 1", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 3", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Sgl. Rod