The spacing (l) of the support must be no more than the values shown in the graph on the right. 200 kg m 190 (2100) (2100) (2100) (2100) 180 170 l 160 150 140 130 Weight m (1800) (1800) (1800) (1800) m l 120 Caution 110 MY1M63 MY1M63 MY1M63 MY1M63 m 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation.

Order Made 180 Made to Order 1200 or less 2000 or less 200 1200 or less 2000 or less Refer to p.5.4-1 for made to order specifications for series CS1. 250 1200 or less 2400 or less 300 1200 or less 2400 or less Second Class Pressure Vessel Rod Boot Materials Symbol Material Max. ambient temp.

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

1200 Ambient temperature 15C Cooling capacity [W] Cooling capacity [W] 1000 1000 Ambient temperature 25C Ambient temperature 25C 800 800 600 600 400 400 Ambient temperature 35C 200 200 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] HECR006-A Circulating fluid: Tap water Circulating fluid: Ethylene glycol 20% 1800 1800

Required flow rate Recommended flow rate = Number of elements FGE 400 L/min or less 800 L/min or less 1200 L/min or less FGG [Recommended flow rate per one element] 400 L/min (Pressure drop 7 kPa to 8 kPa) When viscosity rate is equivalent to water.

MY1MW40 (1300) (1300) (1300) (1300) 60 60 (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) L L 40 40 (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1CW25 MY1CW25 (1000) (1000) (1000) (1000) MY1MW20 MY1MW20 30 30 (1000) (900) (1000) (900) (1000) (1000) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 (900) (900) (900) (900

Slider type LEFB series 3.1 Specification LEFB25,32,40 AC servo motor (100W / 200W/400W/) Model LEFB25 LEFB32 LEFB40 300,400,500,600,700, 800,900,1000,(1100), 300,400,500,600,700, 800,900,1000,(1100), 300,400,500,600,700, 800,900,1000,(1100), 1200,(1300,1400),1500, (1600,1700,1800,1900), 1200,(1300,1400),1500, (1600,1700,1800,1900), 1200,(1300,1400),1500, (1600,1700,1800,1900), Stroke [mm

) (1500) (1800) (2000) (300) 500 (600) (700) 800 (900) 1000 (1200) (1500) (1800) (2000) (kg) 1.19 1.45 1.58 1.71 1.84 1.97 2.10 2.39 2.85 3.08 3.31 3.54 3.77 4.00 4.46 5.15 5.84 6.30 4.12 4.80 5.14 5.48 5.82 6.16 6.50 7.18 8.20 9.22 9.90 (kg) 0.12 0.19 0.35 1( ) 2{-}5m 5m 10% 3() 452000Hz 1 () 4 5 6 7 8 14 LE FB32 LEFB32 12 W(kg) W(kg) 10 8 LE FB25 LEFB25 6 4 LE FB16 2 LEFB16 0 0 500

MY1MW50 MY1MW50 l (1600) (1600) (1600) (1600) (1600) 70 70 MY1CW50 MY1CW50 MY1CW50 m MY1MW40 MY1MW40 (1300) (1300) (1300) 60 60 (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1CW32 MY1CW32 MY1CW32 (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 l l MY1CW25 MY1CW25 30 30 (1000) (1000) (1000) MY1MW20 MY1MW20

MY1MW50 MY1MW50 l (1600) (1600) (1600) (1600) (1600) 70 70 MY1CW50 MY1CW50 MY1CW50 m MY1MW40 MY1MW40 (1300) (1300) (1300) 60 60 (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1CW32 MY1CW32 MY1CW32 (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 l l MY1CW25 MY1CW25 30 30 (1000) (1000) (1000) MY1MW20 MY1MW20

Bore size (mm) Maximum stroke Standard stroke (mm) 32 700 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 40 800 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 1400 25, 50, 75, 100, 125, 150, 175

Order Made 50 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80 Symbol Specifications/Descriptions 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 XA 100 Change of rod end shape 1500 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450,

Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 1200 (12"), +: None, Stroke B: 1200 (12"), Stroke Adjustment: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 4 pcs., Stroke Options: XC10 (Dual Stroke, Double Rod)

Magnet: None, Mounting: L (Foot), Bore Size: 325 (3 1/4"), Stroke A: 1200 (12"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1200 (12"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

1600/1800 1000/1200 1600/1800 2000/2400 2500/3000 Heating capacity(50/60Hz)4 W 400/500 450/500 550/700 Temperature stability 5 0.1 0.13(at 7L/min)/0.18(at 7L/min) Pump capacity (50/60Hz) 6 MPa For option T : 0.42(at 10L/min)/0.4(at 14L/min) 0.13at 7L/min/0.18(at 7L/min) For option MT : 0.32(at 10L/min)/0.32(at 14L/min) For option -T/MT0.36at 7L/min/0.42(at 10L/min) For option T1 : 0.28(

, 1400, 1600, 1800, 2000 25 32 40 Operating temperature range (C) CC ML2B RB It is possible to make 100 stroke up to 2000 by the 1 mm interval.

Cooling Capacity HRSE012-A-10-(T) [50 Hz] [60 Hz] 1600 1400 1600 Ambient temperature Ambient temperature 0 200 400 600 800 1000 1200 1400 25C Cooling capacity [W] Cooling capacity [W] 25C 600 800 1000 1200 HRS HRS 090 35C 35C 0 200 400 HRS 100/150 0 10 20 30 40 0 10 20 30 40 HRSH 090 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH HRSE018-A-10-(T) [50 Hz] [60 Hz]

R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult SMC Customer Service for larger sizes.

R O D B O R E S I Z E 7/16-20 7/16-20 7/16-20 3/4-16 3/4-16 3/4-16 1-14 1-14 1 1/4-12 1 1/2-12 1 7/8-12 5/8 5/8 5/8 1 1 1 1-3/8 1-3/8 1-3/4 2 2-1/2 S TA N D A R D S T R O K E 150 1.5 200 2 250 2.5 325 3.25 400 4 500 5 600 6 800 8 1000 10 1200 12 1400 14 E 1 G 1 3/8 H 1 3/4 J 2 K 2 1/2 L 3 M 3 1/2 Z Please consult P/A Customer Service for larger sizes.