Specifications Bore size (mm) Series Maximum manufacturable stroke (mm) Series Bore size (mm) Maximum manufacturable stroke (mm) CJ1 Applicable Series CJ2 CA2, CBA2 10, 16 40 to 100 300 (Maximum 150 on one side) 1000 CM2 20 to 40 125, 140 1000 1000 CJP Series Vol. no.
CY1H25 (Nm) 64 56 50 40 30 50 40 M1 1.5 10 13 M2 2.5 16 16 M3 1.5 10 13 M1 28 56 64 M2 26 85 96 M3 28 56 64 Model CY1H25 CY1HT25 CY1HT32 Model CY1H10 CY1H15 CY1H20 30 28 26 20 20 CY1H20 CY1H15 16 13 Moment Nm Moment Nm 10 10 2 2.5 3 4 5 3 4 5 CY1H10 M3 2 CY1H10 1.5 1 1 0.5 0.5 70 100 300 500 100 300 500 1000 1000 70 M1 M2 Piston speed mm/s Piston speed mm/s Graph (3) Graph (2) Moment generated
Bore size Stroke Max. stroke (mm) Bore size (mm) Standard stroke (mm) Standard Non-rotating Double rod 8 10 12 16 20 25 10, 25, 40, 50, 80, 100 100 100 400 10, 25, 40, 50, 80, 100, 125, 160, 200 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 200 200 1000 1000 500 Not available with air cushion. Other strokes available on request.
style (D-A73C/A80C) and A9/A9 V style: 1000 V AC/min.
V(mm/s) = x 1000 In case of high pison speed, the use of an auto switch (DF7NT and G5NT) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Keep wiring as short as possible.
Lead wire length (m) Indicator light Yes Yes Yes No No Load voltage Wiring (Output) Auto switch model Pre-wired connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line None (N) DC AC F79 F7P J79 F79W F7PW J79W F7NV F7PV F7BV J79C F7NWV F7BWV 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Grommet Reed auto switch Solid state auto switch
C76F32B C76F40B Standard stroke (mm) 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 Bore size (mm) 32 40 Max. stroke (mm) Mounting bracket 1000 Trunnion Clevis Single knuckle joint Double knuckle joint Floating joint C76T32 C76C32 KJ10DA GKM10-20A JA25-10-150 C76T40 C76C40 KJ12DA GKM12-24A JA40-12-175 20Example of How to Order Data Accessory 1.
Rotary motion theoretical output Graph (1) Cylinder Output on the Extending Side (Double acting) (Nm) Operating pressure (MPa) Size 150 1500 0.15 0.3 0.3 0.4 0.5 0.6 0.7 Tube bore size [mm] 100 1000 32 40 0.34 0.45 0.68 0.90 1.13 1.36 1.58 40 0.64 0.85 1.27 1.70 2.12 2.54 2.97 40 50 400 500 Graph of Effective Output 32 CRB2 3 20 25 30 200 250 300 Operating pressure [MPa] Cylinder output F
V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible.
C76F40B C76F32B Standard stroke (mm) 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 Bore size (mm) 32 40 Max. stroke (mm) Mounting bracket 1000 C76T40 C76C40 KJ12DA GKM12-24A JA40-12-175 C76T32 C76C32 KJ10DA GKM10-20A JA25-10-150 Trunnion Clevis Single knuckle joint Double knuckle joint Floating joint 20Example of How to Order Data Accessory 1.
The maximum detectable piston speed is: Auto switch operating range (mm) _ Time load applied (ms) Operating current of load (OFF condition) > Leakage current V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
If the center of gravity of the total load is not in the center of the shaft, provide a balance weight as illustrated below so that moment in the rotational direction would not be applied to the tip of the piston rod. 0.3 0.2 0.3 0.2 0.7 1 0.5 0.4 Load rate () Graph 2 Cylinder output on the retracting side (Double acting) 1500 150 Tube bore size [mm] 1000 100 40 400 500 40 50 32 200 250 300
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0600 (6 Inch), Adjuster: Adjuster Bolt, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0500 (5 Inch), Adjuster: Adjuster Bolt, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0500 (5 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0300 (3 Inch), Adjuster: Adjuster Bolt, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1000 (10 Inch), Adjuster: BS (Shock Absorber (1 pc.)), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0800 (8 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0200 (2 Inch), Adjuster: BS (Shock Absorber (1 pc.)), Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M
Magnet: D (Built-in), Bore Size: 10 (3/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0200 (2 Inch), Adjuster: Adjuster Bolt, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Horizontal, 0.5M