SMC Corporation of America
Elite Part Number Search
Search Results "NCMB125-0100-X6002"

Magnet: None, Mounting: Basic, Bore Size: 1 1/4", Stroke: 1", Cushion: -, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: None, Mounting: B (Front Nose Mount), Bore Size: 125 (1 1/4"), Stroke: 0100 (1"), Cushion: None, Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)

Magnet: None, Mounting: B (Front Nose Mount), Bore Size: 125 (1 1/4"), Stroke: 0100 (1"), Cushion: None, Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009A (All Stainless Steel, Food Grade Grease)

Mounting: B (Front Nose Mount), Bore Size: 125 (1 1/4"), Stroke: 0100 (1"), Option: XB6 [Heat Resistant (-4F to 300°F)]

Mounting: B (Front Nose Mount), Bore Size: 125 (1 1/4"), Stroke: 0100 (1"), Option: XB7 [Cold Resistant (-22°F to 158°F)]

Magnet: None, Mounting: B (Front Nose Mount), Bore: 125 (1 1/4"), Stroke: 0100 (1"), Cushion: No Cushion, Rod Boot: w/o Boot, Actuation: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XB9 (Low Speed)

Magnet: None, Mounting: Front Nose Mount, Bore: 1 1/4", Stroke: 1", Cushion: No Cushion, Rod Boot: w/o Boot, Actuation: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Low Speed

Magnet: None, Mounting: Front Nose Mount, Bore Size: 1 1/4", Stroke: 1", Cushion: None, Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: All Stainless Steel, Long Stroke Option: -

Magnet: None, Mounting: Front Nose Mount, Bore Size: 1 1/4", Stroke: 1", Cushion: None, Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: All Stainless Steel, Food Grade Grease, Long Stroke Option: -

Magnet: None, Mounting: Front Nose Mount, Bore: 1 1/4", Stroke: 1", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Heavy Duty Wiper

Magnet: None, Mounting: Front Nose Mount, Bore: 1 1/4", Stroke: 1", Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: Stainless Steel Rod

Magnet: None, Mounting: B (Front Nose Mount), Bore: 125 (1 1/4"), Stroke: 0100 (1"), Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel Rod)

Magnet: None, Mounting: B (Front Nose Mount), Bore: 125 (1 1/4"), Stroke: 0100 (1"), Cushion: No Cushion, Rod Boot: w/o Boot, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (Heavy Duty Wiper)

Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder

Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder

Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :