Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -
characteristicsTemperature characteristicsOutput specificationsResponse timeHysteresisPower supply voltageCurrent consumptionResistanceWeightPort size (Rc, NPT, G)PF2A703HDry air, NitrogenHeater type150 to 3000 l/min5 l/minReal-time flow rateAccumulated flow0.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?
Auto Drain Float Type Model NAD600-N10 Minimum operating pressure 45psi. Maximum operating pressure 145psi. 1 NPT top entry. (N10), 3/4 NPT (N06) Model NAD402-N04 (N04 = 1/2 NPT) Minimum operating pressure 22psi. Maximum operating pressure 145psi.
, EA (0.01 m), or EC (activated carbon).
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
DIGITAL FLOW SWITCH, PFA, DIGITAL FLOW SWITCH, 0.00000 lb
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m)