20 25 30 32 40 40 52 52 10 10 10 14 14 85 95 102 123 144 15 17 17 21 21 52 56.5 67 83 98 16 20 20 20 22 12 13 18 23 25 12 15 12 18 20 10 12 15 17 19 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 11 11 14 18 18 22 26 With Rod Boot ZZ ZZ Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 50 63 80 100 Stroke range (mm) e l M MM N P Q H S T V W ZZ f h (Both sides) (One
100 70 15 130 110 150 20 11 22 14 60 80 110 126.5 242 20+0.084 0 MB-S10 100 114 120 90 15 158 132 184 26 13.5 24 17 75 100 136 148.5 261 25+0.084 0 Double clevis pivot bracket B DX Z + Stroke DB DD B 90 4 x DT B A DS DH DO DC DE DO 4 x DR DU DL DA DU With Rubber Bumper [mm] [mm] Bore size Z Part no.
Lead wire length symbols: 0.5 m Nil (Example) A54 3 m L (Example) A54L 5 m Z (Example) A54Z Besides the above models, there are some other auto switches that are applicable.
m 0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 9-6-6 7 Model Selection Series MNB Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 1000 1000 500 400 300 500 400 300 100 100 80 80 200 200 63 63 100 100 50 50 40 40 80 80 100 100 Load weight: m (kg) Load weight: m (kg) CL 63 63 50 40 30 50 40 30 32 32 50 50 40 40 CL1 20 20 32 32 MLGC 10 10 CNG
m 0.3 MPa Graph (5) F 0.4 MPa Graph (6) m 0.5 MPa Graph (7) F 9-6-6 7 Model Selection Series MNB Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 1000 1000 500 400 300 500 400 300 100 100 80 80 200 200 63 63 100 100 50 50 40 40 80 80 100 100 Load weight: m (kg) Load weight: m (kg) CL 63 63 50 40 30 50 40 30 32 32 50 50 40 40 CL1 20 20 32 32 MLGC 10 10 CNG
A Bore size (mm) 32 40 50 63 80 100 125 H 0.5 0 0.1 C DH7 FH11 L M N P 15 32.5 10.5 22 10 14 30 6.6 45 10.5 5.5 5 38 12 25 12 16 18 35 6.6 55 11 5.5 5 51 15 21 20 46.5 27 16 40 9 65 15 6.5 5 56.5 15 32 16 21 23 45 9 75 15 6.5 5 70 27 72 18 36 20 25 45 11 95 18 10 5 89 18 41 20 25 30 55 11 115 18 10 5 40 110 25 50 30 37 60 13.5 140 20 10 7 100 Black color 81 Series CP96/C96 Dimensions
F from 0.4MPa Graph 6 m from 0.5MPa Graph 7 F 31 Selection of Models Series MNB Selection Graphs Graph 5 Graph 2 0.3MPaP<0.4MPa 0.3MPaP<0.4MPa 1000 1000 500 400 300 500 400 300 100 80 200 200 63 100 80 100 50 40 100 100 Load weight: m(kg) Load weight: m(kg) 63 50 40 30 50 40 30 32 50 40 20 20 32 10 10 5 4 3 5 4 3 2 2 1 100 200 300 400 500 1000 1 100 200 300 400 500 1000 Maximum speed: V(mm
The kinetic energy of a load can be found using the following formula. 20 10 5 M 100 300 1000 2000 500 M 2 2 Ek = Maximum drive speed (mm/s) Ek: Kinetic energy (J) M: Weight of load (kg) : Piston speed (m/s) Example) Find the rod end load limit when a 63 air cylinder is operated at a maximum drive speed of 500mm/s.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
The kinetic energy of a load can be found using the following formula. 20 10 5 M 100 300 1000 2000 500 M 2 2 Ek = Maximum drive speed (mm/s) Ek: Kinetic energy (J) M: Weight of load (kg) : Piston speed (m/s) Example) Find the rod end load limit when a 63 air cylinder is operated at a maximum drive speed of 500mm/s.
40 20 14 15.5 19 to 600 32 75 18 104.5 58.5 63 1/4 12 45 17.5 35 27 11 75 134.5 56.5 14 20 40 20 14 16.5 23 to 600 32 90 18 119.5 68 80 1/4 18 45 22 40 32 13 95 169 72 22 30 60 25 20 19 33 to 750 37 102 22 150 81 100 1/4 20 55 25 40 41 16 114 189 89 22 30 60 30 20 19 37.5 to 750 37 116 26 170 96 Bore size (mm) N S U V T P J MM GR GE GF K L Q RR H VA W Z ZZ 32 27 154 13 6.5 34 1/8 10.5 M6
side) 1 15 20 D-P5DWL (n2) 2 (n2) 2 15 + 65 n = 2,4,6,8... 20 + 65 n = 2,4,6,8... n 12
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: Rc, Port Size: 20 (2), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: Rc, Port Size: 20 (2), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: Rc, Port Size: 20 (2), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only)
Rated Flow Range: 120 to 12000 l/min, Thread Type: Rc, Port Size: 2, Output Specifications: Out: NPN; Func: Analog Voltage Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 120 to 12000 l/min, Thread Type: Rc, Port Size: 2, Output Specifications: Out: PNP; Func: Analog Current Output <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 120 to 12000 l/min, Thread Type: Rc, Port Size: 2, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Lead Wire and M12-M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: -
Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: Rc, Port Size: 20 (2), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)