1.3 4.0 0.3 (Note 4) UL Style 2103 AWG20 2 cores Lock cable LE-CSB-RA 2 to 10 LE-CSB-RB 2 to 10 Note 1. d is as shown below. d Conductor Insulation sheath 2.
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 2 (Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration Certificate:
Rated Flow Range: 0.5 to 4L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/8, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Specifications AP501mmA 100 mm Hg absolute to 10 psig (-88 kPa to 0.07 MPa) AP510 1 to 100 psig (0.007 to 0.7 MPa) AP506 1 to 60 psig (0.007 to 0.4 MPa) Select compatible materials of construction for the gas Vacuum to 150 psig (1.0 MPa) 500 psig (3.4 MPa) 1000 psig (6.9 MPa) 40 to 160F (40 to 71 C) (No freezing)1) 0.06 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max
4 5 5 DVA 2H9 2H9 3H9 TB 5 6 6 SC 8 9.5 10 RB 16 18 22 WA RA 18 24 26 VB 2 2 3 XA 2H9 2H9 3H9 XB 2 2 3 Model MHS4-16D MHS4-20D MHS4-25D +0.025 0 +0.025 0 +0.025 0 +0.043 0 +0.052 0 +0.052 0 +0.025 0 +0.025 0 +0.025 0 17H9 21H9 26H9 601 Series MHS4 Dimensions MHS4-32D/40D SB counterbore depth 9 (Mounting hole) 2 x SA through RA AA 6.4 RA AB 3 35 35 5 VA depth VB 8 NA RB RB B XA depth XB 8h9
(1) 0+55() 0+40() -20+65() -15+70() 90%RH() 80%RH() 90%RH() () 1000m LECSS2-T5 LECSS2-T7 LECSS2-T8 LECSS2-T9 () 5.9m/s2 XY49m/s2 (2) (FR-BIF) (UVW), A 5 (UVW)(UVW) U U U U V V M V M V W W W W DC DC 24 V DC 24 V DOCOM DOCOM RA RA U,V,WCN2 (3) (4) A 6 () (5) DC24V ALM()MBR( ) RA B U DC 24 V (6) 10 (7) A 7 () 1.(:) (1) (2) 2.(:) (1) 1 (2) (3) (4) , [](:) EEP-ROM
2 2 27 27 27 27 29 29 29 2 2 2 2 4 4 4 A grease pack (10 g) is included.
Surface finish Surface finish Ra 10 in. (0.25 m) Standard 25 in. (0.62 m) Code Pressure gauge unit 2) No code Q Unit psig/bar MPa Code No code MPA Ports Porting Configuration Ports 2 ports 3 ports 4 ports Code 2) Pressure gauge unit MPa or psig/bar selectable.
Operating Parameters Status Gas Operating pressure Proof pressure Burst pressure Ambient and operating temperature Cv Vacuum to 250 psig (1.7 MPa) Vacuum to 125 psig (0.9 MPa) 1000 psig (6.9 MPa) 8000 psig (55.2 MPa) 14 to 160F (10 to 71C) (No freezing) 1) 0.29 2 x 10-11 Pam3/sec 2 x 10-10 Pam3/sec 2) 4 x 10-9 Pam3/sec 2) Ra max 15 in. (0.4 m) Option: 10 in. (0.25 m), 7 in. (0.18 m), 5 in
2 2 2 2 4 2 2 1 1 6 2 No. !
x M5 x 0.8 16 2 x 4 x OB counterbore RB 2 x 4 x OA counterbore RA Note) 4 x N through Flat washer 4 pcs.
2 @1 @3 e u o t @2 !8 @0 @0 @3 !2 !9 e @0 @1 o t u !8 @0 @2 !1 !4 q w r y !5 !6 i w i !
Proper Auto Switch Mounting Position (Detection at stroke end) 10112122Basic style (B) / CG1WB CG1WB With rubber bumper Relief port 2-M5 x 0.8 GA RA H1 GA 2-P (Rc, NPT, G) MM Rod side air port Relief port Relief port Head side air port RA MM H1 Width across flats B1 1 2 1 2 Width acros flats B1 D D E-0.05 0 E-0.05 0 I H + Stroke K A AL AL C0.1 KA H A K F F 8-J S + Stroke ZZ + 2 Stroke NA
Basic style (Through-hole/Both ends tapped common): CQSK/CDQSK 12 16 Auto switch Minimum lead wire bending radius 10 2 x 2-OB counterbore H thread effective depth C 2-M5 x 0.8 2 x 2-OA effective depth RA Note) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-N through
Note 3) For piping, refer to Specific Product Precautions. 880 Hygienic Design Cylinder Series HYG Dimensions: 32 to 63 Without auto switch: HYG32 to 63 RC RB 4 x RE depth RF RA + Stroke Bottom view M5 x 0.8 4 x TC depth TD (Breathing port on guide) Note 2) QA RB RA + Stroke TA 4 x RE depth RF 4 x RD through MB L RC TB D J G UB QB PC 2 x K 4 x UC depth UD 2 x PE UA (4.7) PA H F P P PB + Stroke
With air cushion 2 x M5 x 0.8 Relief port RA GA WA RA GA WA Cushion valve (Width across flats WH) Cushion valve (Width across flats WH) 10 10 20 20 ZZ + 2 Stroke S + Stroke (mm) A AL Bore size Stroke range Standard Long B1 C D E F GA H H1 I J K KA MM NA P RA S 1 2 ZZ 20 20 20 13 14 14 20 20 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 8 10 12 16 20 20 25 30 14 16.5 20 26 32 38 50 60 13 17 17 19
MGPW series 20 to 63 Upper view of plate Bottom view of cylinder Side view (lower surface) of cylinder 2 N 2 N RA HB XB 2 N XA+(Stroke/2) HA MGPW Series (mm) Bore size (mm) HA HB N RA XA XB 20 25 32 40 50 63 250.02 250.02 280.02 760.03 +0.010 0 17 3H7 depth 6 280.02 280.02 340.02 920.03 +0.012 0 18 4H7 depth 6 340.02 340.02 420.02 1120.03 +0.012 0 19 4H7 depth 6 380.02 380.02 500.02 1280.04