Nil Z None Note) FDBG Note) With indicator light / surge voltage suppressor FDCG Note) Note) Not applicable to the S kit.
Standard Features General purpose pre-filter AFW30-N03-E1 AFW30-N03-E1 AFW30-N03-E1 AFW30-N03-E1 AFW30-N03-E1 AFW30-N04-E1 AFW60-N04-E1 AFW60-N04-E1 Simplex Simplex Simplex Simplex Simplex Simplex Duplex Duplex B C Inlet flow rate Model CFM 6 8 10 15 22 33 44 66 168 222 282 420 624 930 1248 1866 Connection size Model 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 3/8"NPT 1/2"NPT 1/2"NPT Pipe size
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
Pitch) 2n x One-touch fittings Applicable tube T0425 (A, B port) (Pitch) VK VK VT Refer to the above drawing for other dimensions.
Without sub plate Side port Rc1/4 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 Side port Rc3/8 Bottom port Rc1/4 FHG Bottom port Rc3/8 1 (P) 5 (R1) 3 (R2) Port R is Rc3/8 (A) 4 (B) 2 Seal type FJG Nil R Metal seal Rubber seal 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 Options FPG Nil N None Indicator light Indicator light with surge voltage suppressor Individual pilot exhaust 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 Z
CE UL(CSA)RoHS 50 g 100 g 1OFF (2 5 ) 5 100 (24 5 min100 500 min9.5 ) 290(7 s) 390(7 s) -67No.PF-OMN0011CN-C 0100 1 / -10110 1 3F.S. 7 s 2 5F.S. 1090 2 (ZS-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504
Local Area: (800) 258-9200-www.stevenengineering.com 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 Sub-plate port size Thread type Rc Nil Without sub-plate Side ported Rc 1/4 Nil A02 A03 B02 B03 YZ NPTF T G F Side ported Rc 3/8 Bottom ported Rc 1/4 1 (P) 5 (R1) 3 (R2) Bottom ported Rc 3/8 (A) 4 (B) 2 Port R is Rc 3/8 Seal FHG Nil R Metal seal Rubber seal 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 Option FJG Nil Z
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature:
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 2 (Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration
Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration Certificate: None
Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None,
Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration Certificate: None
Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration Certificate:
With light/surge voltage suppressor Z When an external pilot valve is to be used, enter a symbol in section (b) of the station table below. eStation Table Indicate the layout of valves, etc. with symbols. When the sizes of ports A and B are mixed, indicate in section (a) with C4, C6 and M5.