.: 32mm), Output Specification: 1 (OUT1: Analog 1 to 5V), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: A (Calibration Certificate)
.: 32mm, Output Specification: OUT1: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -
.: 32mm, Output Specification: OUT1: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate
.: 32mm, Output Specification: OUT1: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: -, Calibration Certificate: -
PF3W5 -1 (Analogue 1 to 5 V type: Without temperature sensor) Flashes twice. PF3W5 -2 (Analogue 4 to 20 mA type: Without temperature sensor) Flashes three times. PF3W5 -1T (Analogue 1 to 5 V type: With temperature sensor) Tighten to the specified torque for piping.
Rated Flow Range: 11 (10 to 100 L/min), Port, PVC Pipe O.D.: 25 (Port Size: 25A, Pipe O.D.: 32mm), Output Specification: 2 (OUT1: Analog 4 to 20mA)
Rated Flow Range: 10 to 100 L/min, Port, PVC Pipe O.D.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: Analog 4 to 20mA, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -
relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 JIS B 8433-1993: 2) : : : 1. 2. 3. 1. 2. 3. 4
FLOW Hysteresis 1 Hysteresis 1 SET Set point 1 Set point 2 button (UP) button (DOWN) button (SET) ON Item Default settings Model Item Default setting Instantaneous flow PF2A2 series [10L] 1 to 10 L/min type (PF2A510) Connecting the wiring Attaching the sensor connector to the sensor wire Strip the sensor wire as shown. Do not cut the insulator.
.: 32mm), Output Specification: 2 (OUT1: Analog 4 to 20mA), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket)
Rated Flow Range: 10 to 100 L/min, Port, PVC Pipe O.D.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -
lock ring/Without lock ring) Bellows (B)/With Lock Ring Buffer Mounting Nut Pad diameter: 6 to 8 ZP06B to 08B Model d H B C NTJ-015A 9.2 8 4 M8 x 1 M6 x 1 M5 x 0.8 SNJ-006A 9.2 8 3 SNJ-010A 3 12 13.9 SNJ-015A 16.2 14 3 M10 x 1 M14 x 1 SN-015A 21.9 19 5 Pad diameter: 10 to 50 ZP10B to 50B Model Size B06 A 6 ZP06B B 7 C 2.5 D 7 E G 3.3 H 9.1 Y 4 F 13 B08 8 ZP08B 9 2.5 7 13 4.7 10.1 4 B10
(Example): CDU20-25D Bore size 6, 10, 16, 20, 25 32 32 32 Type M5 x 0.8 Rc 1/8 NPT 1/8 G 1/8 Symbol D Double acting CU Nil TN TF CQS Standard stroke (mm) 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40, 50 CQ2 RQ Applicable Auto Switches/Refer to pages 1263 to 1371 for further information on auto switches.
Flow ranges (lpm): 10-100; Port sizes: 25A (32mm O.D.) ; Temperature rating: 0-70°C; Output options: NPN/PNP, (switch); 1-5V, 4-20mA; Accuracy: ±3% F.S.; Repeatability: ±2% F.S.
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -