Pressure switch for vacuum with energy saving function Circuit diagram ZL6 -K2 B2 5 Z -E F ZL6 -K2 B2 5 Z With supply valve and release valve With pressure switch for vacuum with energy saving function ZL6 -K1 B1 5 Z ZL6 -K15L0Z-V W With supply valve With supply valve and vacuum pressure switch Specific Product Precautions 30 A ZL1/ZL3/ZL6 Series Specific Product Precautions 1 Be sure to

With light/surge voltage suppressor Z When an external pilot valve is to be used, enter a symbol in section (b) of the station table below. eStation Table Indicate the layout of valves, etc. with symbols. When the sizes of ports A and B are mixed, indicate in section (a) with C4, C6 and M5.

Example) IS10M-30-6LP Symbol Description Nq Body size 20 30 40 50 60 a Set pressure range Nil 0.1 to 0.4 MPa 61 0.1 to 0.6 MPa + Semi-standard Nil 0.5 m L 3 m Z 5 m + b Lead wire length Nw 23 15 (13) c Pressure unit of the scale plate Nil MPa P2 MPa/psi dual scale (23) (5000) (3000) (500) 1 Set pressure range of 6P (L, Z) is 0.2 to 0.6 MPa (30 to 90 psi). 2 This product is for overseas use

A02 A03 A04 A06 A10 B02 B03 B04 B06 Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/4 Side-ported 3/8 (A) 4 (B) 2 Rated coil voltage Side-ported 1/2 FHG 3 4 24 VDC Side-ported 3/4 12 VDC 1 (P) 5 (R1) 3 (R2) Side-ported 1 Voltage other than above (50 VDC or less) 9 (A) 4 (B) 2 Bottom-ported 1/4 Bottom-ported 3/8 FJG Bottom-ported 1/2 1 (P) 5 (R1) 3 (R2) Option Bottom-ported 3/4 Nil Z

Nil A 4 (A) 4 (B) 2 S With surge voltage suppressor A 2 With light/Surge voltage suppressor B SOL.b SOL.a Z 3 (R) 5 (R) 1 (P) 4 position dual 3 port valve: N.O./N.O. (A) 4 (B) 2 Electrical entry B MN: Without lead wire MO: Without connector M: With lead wire (length 300mm) SOL.b SOL.a 3 (R) 5 (R) 1 (P) 4 position dual 3 port valve: N.C./N.O.

ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 V A M W 1 1 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 4) 2) 1) 3 300L/min(ANR) M 0.35MPa *2 P 6 600L/min(ANR) H 0.50MPa 3)P V/ *23 (V) (P) 5/ 06 Rc3/4 K1 N.C.+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.

Series CM2-Z P .352 P .356 P .474 Air Cylinder Air Cylinder Air Cylinder Series CG1-Z Series MB-Z Series CA2-Z P .592 P .686 P .750 Compact Cylinder/Double Clevis Pivot Bracket Cylinder with Stable Lubrication Function (Lube-retainer) Floating Joint: For Pneumatic Cylinders (180, 200) JA-X530 Series CQ2/CQS Series CM2-Z/CG1-Z/CA2-Z/CQS/ CQ2-Z/MXQ/MGP-Z/CXS P .830 P .832 P .842 1 This is a

S L, Z Thread AC Flange DC Note) Surge voltage suppressor is attached to the lead wire.

1 2 A 1A VXN Z 1 2 A A Enter standard product number.

Only Z and NZ types are available for the product with power saving circuit. Select a valve from R, U, S or Z when the SI Unit common is positive common.

T[s] = (V/10) X (T2 T1)/(Z) T(s) = (4.8/10) X (12 3.7) = 4 NO NO Increase number of booster regulators (Z) to decrease T.

If it must be installed in an environment with poor noise conditions, eliminate the power supply noise by using a line filter, Z-wrap, or a spark killler on the 100 V power supply or signal source line. The length of the power suply and signal lines must be kept as short as possible.

Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch.  Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility.  Designed to work with fluids up to 90ºC

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector)

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector)

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V)

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA)

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor)

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -