SMC Corporation of America
Elite Part Number Search
Search Results "PF3W720S-F04-AT-MR"

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

D-J51: 5 ms or less Except D-J51 (1 mA or less at 100 VAC, 1.5 mA or less at 200 VAC), D-M5NW/M5PW/M5BW, D-F9BAL, D-P5DWL (1 mA or less at 24 VDC).

Mount a switch at the center of the operating range. Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON). (The mounting position shown in a catalog indicates the optimum position at stroke end.)

Adjust the mounting position of an auto switch so that the piston stops at the center of the operating range (the range in which a switch is ON). (The mounting position shown in a catalog indicates the optimum position at stroke end.) If mounted at the end of the operating range (around the borderline of ON and OFF), operation will be unstable.

SRH VBA20A-03 VBA20A-F03 VBA10A-02 VBA10A-F02 VBA11A-02 VBA11A-F02 G27-20-01 AN20-02 ANA1-02 KT-VBA10A-18 VBA40A-04 VBA40A-F04 VBA22A-03 VBA22A-F03 VBA42A-04 VBA42A-F04 VBA43A-04 VBA43A-F04 Model Description Pressure gauge Silencer High-noise reduction silencer Elbow for silencer SRP G N S L G36-10-01 AN30-03 ANA1-03 KT-VBA22A-7 AN30-03 ANA1-03 G36-10-01 AN40-04 ANA1-04 G27-20-01 AN40-

Theoretical output table 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 63 The value at the OUT side is the same as the double acting single rod type, but the value at the IN side is different.

Piston rod lurching, due to cracking pressure at start up, has been eliminated by means of a floating seal mechanism.

The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.

(Make sure to use it at the allowable rotational torque or less.)

(Make sure to use it at the allowable rotational torque or less.)

Caution Caution Apply air pressure of at least 0.20MPa to the port on the retracting side. This is necessary to release the lock. This is necessary for proper operation and release of the lock. W Exhaust Speed Caution Locking will occur automatically if the pressure applied to the port on the retracting side falls down to 0.05MPa or less.

Therefore, make sure that the mounting pitch of the cylinders is at least that indicated in the table below. (mm) (mm) Part No. Size Dd9 H D L Part No.

MNB CNA Maximum piston speed: 500 mm/s It can be used at 50 to 500 mm/s provided that it is within the allowable kinetic energy range. (The lock-up cylinder can operate at 50 to 200 mm/s.)

Fine lock series (Series CLJ2/CLM2/ CLG1) Maximum load at horizontal mounting: 70% or less of the holding force (Maximum static load) for spring lock Maximum load at vertical mounting: 35% or less of the holding force (Maximum static load) for spring lock Lock-up series (Series CL1) Maximum load at horizontal mounting: 50% or less of the holding force (Maximum static load) Maximum load at

When the overrun amount exceeds this range, self-holding of the contact should be performed at the switch load side. If the lock is applied at a desired position of a stroke and compressed air is applied to only one side of the cylinder, the piston will lurch at a high speed the moment the lock is disengaged. In such a situation, there is a risk of injury to humans, or equipment damage.

rod end when the air cylinder 63 is actuated at 500 mm/s.

The same result will be caused by clogging of the silencer installed at the EXH port of the solenoid valve.

How to Assemble and Replace Silencer Assembly (ZL6) The silencer assembly of the ZL6 series is not attached at the time of delivery. Please attach it before use. As shown in Fig. 1, align the hooks of the silencer assembly with the grooves on the body, and push in the direction of the arrow until it clicks.