1 et y u o !0 q !6 r RJ10, 14, 2015, 2725 w i !2 r !3 !1 q e t y u o !0 !6 Component Parts No. Material Treatment Description No.
NBR, FKM t Aluminum alloy Piano wire y u i Note) et components determine the valve composition. Replacement Parts Part no. Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.
(16 points) 16 0 EX600-DY *B (8 points) 0 8 Digital output unit EX600-DY *E (16 points) 0 16 (EX600 Series) DY EX600-DY *F (16 points) 0 16 EX600-DM *E (8/8 points) 8 8 Digital I/O unit (EX600 Series) DM EX600-DM *F (8/8 points) 8 8 Analog input unit AX EX600-AXA*1 (2 points) 32 0 Analog output unit AY EX600-AYA*1 (2 points) 0 32 Analog I/O unit AM EX600-AMB*1 (2/2 points) 32 32 *1: User
Ex.mCG:23R Body slzo 1 0 M 5 20_ya 3 0 _ % 10-tA 50-.A 6 0 1 Polt thread [ NPT Nll Rc (PT) F P F Series NAL Lubricator NAL5qD.6{X'O Flow Characteristics Gonstruction./Parts List NAL5flXh6IXXI tlaln Part8 O I Body I Platinum silver pairiting a I HoGing I Alrminum die cas'ting Parts List 1 1 1 7 1 0 Attachments 3/a'1 Allows for ease of installation and maintenance. Gffi@ NE60.
Template DKP50047-F-085D Avoid repeating sudden charges and discharges of the air tank. These may cause the temperature of the product the exceed the maximum allowable value. Danger Do not exceed any of the specifications listed on the label, in section 2 of this document or on the customer drawing. Air equipment has air leakage as standard within certain limits.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: N (w/o Lead Wire and M8 Connector)
Stations: 4 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: Integrated Display, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 3/4, Return Unit Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
: °F), Bracket: None, Calibration Certificate: None
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature:
Reference formulae [Dynamic moment at impact] Use the following formulas to calculate dynamic moment when taking stopper impact into consideration. m : Load mass (kg) F : Load (N) FE: Load at acceleration and deceleration (N) a : Set acceleration (m/s2) : Set speed (mm/s) M : Static moment (Nm) FE = m a Nominal size Maximum load weight (kg) 16 5 25 10 L1 : Distance to the loads center of
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Stations: 08 (8 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: F (G), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Return Port Size: 06 (3/4), Flow Switch Output Specifications: E (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Valve; w/Stop Valve), Return Port Size: 06 (3/4), Flow Switch Output Specifications: L2T [Out 1: IO-Link/Switch Output (N/P); Out 2: Flow Rate/Temp.: Switch Output (N/P); Temperature Sensor: Yes], Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Flow Switch Unit Specifications: M (Integrated Display: L/min; Accumulated Flow: L; Temp.: °C; Integrated Display IO-Link: L/min; Accumulated