Poppet valve assembly Release flow adjusting needle assembly Sound absorbing material Supply adapter Round head combination screw Supply pilot valve Release valve Pressure sensor O-ring Filter element 3 4 5 6 7 ZR ZA1-SAE2 XT631-ZA1-KA2 M2 x 12 VQ110VQ110PSE54-R04 3.0 x 1.0 ZA1-FE-30 ZM 8 9 10 11 ZMA ZQ q w e t y u !0 !1 !
PE Compact pressure sensor P PSE541-R04 Supply valve P Circuit diagram V -15No. TQ1230001-OM103-A 4.4. FANUC CRX Plug-in software The CRX plug-in software enables easy connection and mounting of the vacuum gripper to the robot. 1.
PE Compact P pressure sensor Supply valve PSE541-R04 P Circuit diagram V -15No. TQ1230001-OM101-D 4.4. URCap Installation and basic setting 1.
PE Compact P pressure sensor PSE541-R04 Supply valve P Circuit diagram V -15No. TQ1230001-OM102-B 4.4. TMComponent TMComponent is an independent software package for the robot applications and you need to import the software package to use in TMflow (robot software) directly. Here is the list of the SMC Vacuum Gripper TMComponents.
Cable Length: 15m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
Cable Length: 20m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
Cable Length: 10m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
Cable Length: 5m, Connector: C [Extension Cable (w/R04-P8F7.3 Connector)+ Connector(R04-J8M7.3)]
specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa -50 to 525 kPa 1 kPa PSE530, PSE540
specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa -50 to 525 kPa 1 kPa PSE530, PSE540
specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa -50 to 525 kPa 1 kPa PSE530, PSE540
Be sure to hold the body when handling. 3Refer to the operation manual of the pressure sensor PSE540 series (on SMCs website URL http://www.smcworld.com) for instructions on how to terminate the connectors of this sensor. 53 - Doc. no. ZB-OM00201-B Vacuum Pressure Switch Assembly Handling Precautions 1) Do not drop, hit or apply excessive shock (100m/s2) to the product.
specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa -50 to 525 kPa 1 kPa PSE530, PSE540
Refer to the Operation Manual of the pressure sensor PSE540 series for how to connect the connectors for sensor. 3. Malfunctions stemming from noise may occur if the wire is installed in the same route as that of power or high-voltage cable. Wire the switch independently. Environment Caution 4.
Refer to the Operation Manual of the pressure sensor PSE540 series for how to connect the connectors for sensor. Common PV port Common PS port Common PD port 8 One-touch 6 One-touch ZK2-MP1C6-A There are 4 types depending on the manifold port specification.
(ANR)] [L/min(ANR)] [KPa] [KPa] [MPa] [L/min(ANR)] 38 - No.ZB-OM00301 0.3 / ZB03-Q1/Q2 (0.5MPa ) [L/min(ANR)] [L/min(ANR)] [KPa] [KPa] [L/min(ANR)] [MPa] 0.4 / ZB04-Q1/Q2 (0.5MPa ) [L/min(ANR)] [L/min(ANR)] [FPa] [FPa] [L/min(ANR)] [MPa] / ZB000-K1/J1 V V450 [KPa] [L/min(ANR)] 39 - No.ZB-OM00301 Pmax Qmax V0 Pmax V P1-Q1 VQmax 0 V 0 Assy 15VPSE200PSE300 2 980m/s 50N PSE540
Air supply port Urethane pad Recommended sensor Pressure sensor PSE540 Series Flow sensor PFMV Series For the method of selecting and using a sensor, refer to the operation manual. 728 Non-contact Gripper XT661 Series Low Profile Cyclone Type (-X260) Made to Order Low profile Thickness: 1.8 mm Weight: Approx. 1.3 g* Outer body diameter (mm) 20 25 Air consumption [L/min (ANR)] 31 31 * Outer
Compact Pneumatic Pressure Sensor PSE540 Series.Features· Manifolding is possible.· Pads can be directly mounted.
. , , ,1.5~2 1. , ,1ISO VG32 ,, ,, 2 ,,A /B 90 4 ,0.01mm 2-1 2-2 2-2-1 () B L F 0.5m L 3m 12 12 20 20 (mm) Z 255075100 () 2-2-2 A90 D-A90 F9N D-F9N F9NW D-F9NW A93 D-A93 F9P D-F9P F9PW 2 D-F9PW A96 D-A96 F9B D-F9B F9BW D-F9BW A90V D-A90V F9NV D-F9NV F9NWV D-F9NWV A93V D-A93V F9PV D-F9PV F9PWV D-F9PWV A96V D-A96V F9BV D-F9BV F9BWV D-F9BWV F9BAL D-F9BAL , 2-2-3 *1 C R04
Resistance Square Wave (1s Pulse Width) 1500V at Power Terminal, 600V at Input Terminal Impact Resistance 10G, 3 times at each axis Proof Voltage AC1500V, 1Min (less than 3mA), between Case & AC Line AC500V, 1Min (less than 3mA), between Case & 12VDC Current Consumption Below 1.0A Insulation Resistance Above 50M, between Case & AC Line Mass 690g 22 5-3 Sensor Specifications Connector Connector : R04