SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ5-43P-04-C4"

7) IS1000M-60 IS1000M-50 Y510-(02) 03 IS1000M-20 IS1000M-30 IS1000M-40 IS1000M-50 IS1000M-60 Y610-03 (04) Y610-(03) 04 T-interface Note 6) Note 7) Y110-M5 Y110-M5 VHS20-01 02 VHS50-06 10 3-port valve for residual pressure release Note 7) VHS30-02 03 VHS40-06 01 E200-02 03 02 E300-03 04 E600-06 10 E100-M5 Piping adapter Note 7) E500-06 E100-M5 01 IS1000E-2002 03 02 IS1000E-3003 04 Pressure

(When port sizes for A, B ports are mixed, indicate C4 or C6 in cell .)

02 12 02 04 02 9 stations 4 stations 12 stations 4 stations 2 stations 2 stations 2 stations 2 stations (2) (2) (2) (2) Specified layout (Up to 8 solenoids possible.)

L-bracket 53 Quick Exhaust Valve with One-touch Fittings 90-AQ240F/340F Series How to Order IN, OUT port applicable tubing O.D. 04 4 Exhaust port Body size 04 Applicable tubing O.D. 4 2 M5 04 90 04 AQ 2 4 F 0 3 4 F 0 06 AQ 06 90 Exhaust port Series compatible with secondary batteries 06 Applicable tubing O.D. 6 90 Material restriction IN, OUT port applicable tubing O.D.

When the port size of the external pilot block assembly is 4, indicate with C4 in section (c).

JSY1000 manifold pitch for C2 and C4 is 6.5 mm, and 9 mm for C6.

, M5 60.3 C3: One-touch fittings for 3.2 Manual override C4: One-touch fittings for 4 C6: One-touch fittings for 6 M5: M5 thread (C3,C4,C6) 47.5 9.5 (M5) 26.5 25.5 5.4 18.5 5 23.2 Mounting holes 10 (47.5) 3-M5 X 0.8 P, R port 9.9 9.9 5 1 3 2-PE port 22.2 Die cast hole For manifold gasket positioning L plug connector (L): VQZ122 wLwC3, C4, C6, M5 0 1 M plug connector (M): VQZ122 wMwC3, C4

SS5YJ3-32-C4 SYJ33 1/8 Type SS5YJ3-S32-M5 Type SS5YJ3-S32-C4 Type SS5YJ3-41-M5 Base mounted for internal pilot Type SS5YJ3-41-C4 SYJ34 1/8 Type SS5YJ3-S41-M5 Type SS5YJ3-S41-C4 Type SS5YJ3-46-M5 Type SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 Type SS5YJ3-S46-M5 Type SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying

-32-C4 SYJ33 1/8 SS5YJ3-S32-M5 SS5YJ3-S32-C4 SS5YJ3-41-M5 Base mounted for internal pilot SS5YJ3-41-C4 SYJ34 1/8 SS5YJ3-S41-M5 SS5YJ3-S41-C4 SS5YJ3-46-M5 SS5YJ3-46-C4 1/8 M5 x 0.8 SYJ34 SS5YJ3-S46-M5 SS5YJ3-S46-C4 Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on

Description Material Aluminum die-casted Note Body q Spool/Sleeve Stainless steel Metal seal w Spool valve Aluminum/HNBR Rubber seal Piston Resin e r Pilot valve assembly For How to Order Pilot Valve Assembly, refer to page 4-14-19. 4-14-7 Body Ported 8 Series VQZ100/200/300 Dimensions: VQZ100 Single unit Grommet (G): VQZ115-G-C3/C4/C6/M5-PR C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4

(M): VQZ115-lMl-C3, C4, C6, M5-PR (Lead wire) Cover dia 1.5 Cross section 0.23mm2 300 60.5 65.5 300 55.5 59 (Lead wire) Indicator light Indicator light 40.5 41.5 Cover dia 1.5 Cross section 0.23mm2 : AC : AC 2.10-8 VQZ100/200/300 Body Ported VQZ200 Valve single unit 2-C4, C6, M5 Grommet (G): VQZ2l2(R)-lGl-C4, C6, M5 C4: One-touch fittings for 4 C6: One-touch fittings for 6 2-3.5 Mounting

-LLL (Lead wire length) 148.3 Insulator: Red (+) Insulator: Black () 0.3 mm2 4.1 5.9 51.2 03 04 Terminal type (TT) 53-SY9140-TTMax. 10 L (Lead wire length) 165.1 Lead wire marking No. 1 (+), No. 2 () 0.75 mm2 48.5 29 Base Mounted Series 53-SY5000/7000/9000 Dimensions: 53-SY9000 2-position double L-type plug connector (L) 53-SY9240-L03 04 29 30 17.5 106 86.5 51.2 2 x 5.4 (For mounting) 25

(The standard valve has an individual exhaust for the pilot valve.) 1.12-58 Series VQZ Base Mounted Replacement Parts One-touch Fitting Assembly (For cylinder port) C3 C4 C6 C8 C10 Fitting Size Series VQZ1000 VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-51A-C8 VQZ2000 VVQ1000-51A-C4 VVQ1000-51A-C6 VVQ2000-51A-C8 VVQ2000-51A-C10 VQZ3000 SY VVQ2000-51A-C6 Note) Order is accepted in

A White Normally Open B Red Normally Closed Mounting & Wiring ZSE ISE IFW50--01 to 04/11 to 14/21 to 24 Caution PSE 1. Mount a switch, so that the liquid flow is in the same direction as that of the arrow on the body. 2. The flow switch can be installed either horizontally or vertically. 3.

Piping: 43 (Base Mounted Common SUP Individual EXH), Stations: 4 Stations, A B Port Size: C4 (ø4 One-touch Fitting)

C4/C6 One-touch fitting C4/C6 One-touch fitting (elbow type) Outstanding seal performance The new rubber seals offer improved durability and performance. Valve failures due to line contaminants have been greatly reduced. (Ozone resistant seals available by special order.)

06 08 10 12 16 Symbol 01 02 03 04 06 Tubing O.D. mm 4 6 8 10 12 16 Hose O.D.

(The standard valve has an individual exhaust for the pilot valve.) 4-14-40 41 Series VQZ Replacement Parts Base Mounted One-touch Fitting Assembly (For cylinder port) C3 C4 C6 C8 C10 Fitting size M5 (VQZ100 only) Model VQZ100 VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-50A-M5 V100 VQZ200 VVQ1000-51A-C4 VVQ1000-51A-C6 VVQ1000-51A-C8 VQZ300 VVQ2000-51A-C6 VVQ2000-51A-C8 VVQ2000-51A-C10

Size and weight reduced by eliminating the manifold base C4/C6 One-touch fitting C4/C6 One-touch fitting (Elbow type) SZ3000 Series Height 31% reduction (Compared with SX3000-45 with DIN rail manifold and 5 stations) FREE LOCK Weight 12% reduction M5 port block assembly A port 1-3-1 B port 2 Series SZ3000 Precautions 1 Be sure to read before handling.