How to Order VFN212 02 N 5 F D Z CE marking NAMUR Interface Nil Q CE marked product Voltage Thread type 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC 6 12 VDC 7 240 VAC, 50/60 Hz Nil Rc (PT) F G (PF) N NPT Electrical entry Solenoid G Grommet E Grommet terminal T Conduit terminal D DIN terminal Nil Single solenoid D Double solenoid Manual
Flow Rate Characteristics Weight (g) Flow rate characteristics 12 (PA) 23 (AR) Model Weight VFN212N-5D-02F 240 VFN212N-5D-02F-D 380 C b Cv C b Cv 2-position Single solenoid 2.68 0.40 0.72 5.41 0.31 1.38 Double solenoid 2.68 0.40 0.72 5.41 0.31 1.38 189 A
I f "n pcs I Non-rotating rod Standard Auto switch See ctalDg N302 for avajlabie Rod boot'r.
I/F DICOM CN3-5 DC24V(DC24V10% 150mA) DC24V CN3-10 DC24V I/F DOCOM CN3-3 EM1LG DC24V DC24V LG CN3-1 MO1MO2 CN3-11 SD 3 22 3 3.6 OFFON CPU () ON ON OFF OFF ON ON OFF OFF ON ON ON () OFF () OFF 1s ON ON () OFF 50ms 60ms () OFF 50ms 60ms .
Controller ID: 1 Function code: 05h Start address: Y30 Data value to be written: "FF00h" (i) Request Example 1 Start code 2 ID 0 Controller ID: 1 3 1 4 Function code 0 Function code: 05h 5 5 6 0 Address No. of 7 0 contact to be Start address: Y30 8 3 written 9 0 Data 10 F 11 F Data value to be Data value to be written: "FF00h" written Note 1) 12 0 13 0 Calculated 14 value Checksum(LRC) 15
fl 110+559120+559 Differenl 1 5 90 100 1 1 0 Same 90 100 1 1 0 Ditterent 15+5d!
fl 110+559120+559 Differenl 1 5 90 100 1 1 0 Same 90 100 1 1 0 Ditterent 15+5d!
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: None, Port Size: C6 (ø6 One-touch Fitting)
Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: None, Port Size: ø6 One-touch Fitting, Thread: -, Option: -, CE Compliant: -
Fitting Type: L (Elbow), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 5D (Tube O.D. 3/4", Tubing Size 1/2"x3/8"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: F (Female), Thread: N (NPT)
Fitting Type: B (Branch Tee), Metric Size, Side A: No (Select Inch Size, Side A), Inch Size, Side A: 5D (Tube O.D. 3/4", Tubing Size 1/2"x3/8"), Metric Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Inch Size, Side B: No (For Types H and L, and Types B or R w/Same Tubing Size), Piping: F (Female), Thread: N (NPT)
This is a legacy product, and replaced byVFS1120-5D-01T-F
This is a legacy product, and replaced byVFS2120-5D-02T, VALVE SOL/PILOT 24VDC *LQA, VALVE, VFS2000 SOL VALVE 4/5 PORT, ED, VFS2000 BODY PT 1/4NPT (F), .65036 lb
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: None, Manual Override: None, Port Size: N7 (1/4" One-touch Fitting), Thread: M Thread, Rc, Option: F (Bracket)
Function: 2 Position Single, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: None, Port Size: 1/4" One-touch Fitting, Thread: M Thread, Rc, Option: Bracket, CE Compliant: -
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LN (L Plug Connector w/o Lead Wire), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: None, Port Size: C6 (ø6 One-touch Fitting), Thread: M Thread, Rc, Option: F (Bracket)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: E (Manually Operated), Port Size: C6 (ø6 One-touch Fitting), Thread: M Thread, Rc, Option: F (Bracket)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: None, Manual Override: None, Port Size: C6 (ø6 One-touch Fitting), Thread: M Thread, Rc, Option: F (Bracket)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: D (DIN Terminal w/Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: None, Port Size: C6 (ø6 One-touch Fitting), Thread: M Thread, Rc, Option: F (Bracket)
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: None, Port Size: C6 (ø6 One-touch Fitting), Thread: M Thread, Rc, Option: F (Bracket)