SMC Corporation of America
Elite Part Number Search
Search Results "SYJ514-5MS"

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .16591 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .17288 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .31570 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .16446 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .17762 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .20787 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .36532 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .32524 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .25527 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .14431 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .21801 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, 10 lb

Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, F29, 10 lb

10ms 5ms Maximum inrush current 0.7A 1.5A 0.7A 1.5A 7A 0.7A 1.5A 7A Maximum power 3W 4W 3W 8W 6W consumption ANALOGUE INPUT CHARACTERISTICS AC INPUT CHARACTERISTICS 10 6 inputs from I01 to I06 Input voltage 100-240 VAC + 10% 15%, 20 8 inputs from I01 to I08 50-60 Hz Measurement range 0-255 Input impedance >or = 800 kOhms Resolution 8 bits 10 000/256mV Pull-in votage at logic state 1 80V

OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 8 Series PSE Operation : Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5ms 20ms 160ms 640ms SET Press SET button.

Primary pressure normal Primary pressure drop Primary pressure increase P1 Set value P2 Time ON Switch output 1, 2 OFF Time [ ] Switch output response time 5ms or more 10ms or less when auto shift is input. Hi Auto shift input Lo 3 types of piping Different piping methods are possible to accommodate the installation location.

For Dry Air, Pilot Operated 2 Port Solenoid Valve Series VQ20/30 Compact & lightweight with large flow capacity Weight (g) Effective area (mm2) 46 9 (Cv0.5) VQ20 VQ30 80 17.5 (Cv1) Series VQ30 VX VNl VQ Series VQ20 High frequency operation possible and long operating life High speed response 5ms or less (VQ20), 20ms or less (VQ30) (Without indicator light and surge voltage suppressor, at

Quick response: valve response time: 5ms; vacuum response time: 28ms, Compact & lightweight: 0.101 lbs (46g) single unit weight, Air pressure and release pressure can be adjusted separately, Simple installation and removal, Available with pressure sensor or vacuum pressure switch VACUUM EJECTOR. VACUUM EJECTOR. 46.00000 lb. M02.

4.8), Coil rated voltage: 12, 24VDC; 100, 110, 200VAC, Response time: 5ms or less (VQ20); 20ms or less (VQ30), Ambient/fluid temp: -10 to 50C VQ1000/VQ20/VQ30 VALVE. VALVE, SOL. VALVE. VQ1000 BUILT IN FITTING >1/4. 0.24912 lb. WD.