SMC Corporation of America
Elite Part Number Search
Search Results "SYJ7120-5G-01-F"

Types 10, 20 Types 10, 20 VVDW 0 2 C 1 01 2 VVDW 2 0 4A Series Series 1 2 10 20 Thread type 1 2 10 20 Rc G NPT Nil F N Material Brass Stainless steel C S Type 30 OUT port size Stations VVCW20-4A Symbol M5 01 Port size M5 1/8 (6A) For 2 stations For 3 stations 1 2 Type 10 is M5 only.

Types 10, 20 Types 10, 20 VVDW 0 2 C 1 01 2 VVDW 2 0 4A Series Series 1 2 10 20 Thread type 1 2 10 20 Rc G NPT Nil F N Material Brass Stainless steel C S Type 30 OUT port size Stations VVCW20-4A Symbol M5 01 Port size M5 1/8 (6A) For 2 stations For 3 stations 1 2 Type 10 is M5 only.

Types 10, 20 Types 10, 20 VVDW 0 2 C 1 01 2 VVDW 2 0 4A Series Series 1 2 10 20 1 2 10 20 Thread type VC Rc G NPT Nil F N Material VDW C S C37 SUS Type 30 VQ VVCW20-4A OUT port size Stations Symbol M5 01 Port size M5 1/8 (6A) For 2 stations For 3 stations 1 2 VX2 VX Type 10 is M5 only.

C C1 L L1 L2 L3 L Individual wiring V V V V F D-sub connector V V P Flat ribbon cable connector V V 8 (Common PV) 6 (Common PS) P Vacuum pump system PN 5/16"(Common PV) 1/4" (Common PS) 10 10 stations 1 Common wiring F/P is available only for solenoid valve wiring. Individual wiring is specified for vacuum switches and sensors.

Description IR1000 IR3000 IR3020/3120 IR2020/2120 IR3010 IR1020 IR2000 IR2010 IR1010 Bracket Pressure gauge P36203018 P36202028 P36201023 G43-2-01 G43-4-01 G43-10-01 G43-4-01 G43-10-01 G33-4-01 G33-10-01 G43-2-01 G33-2-01 Accuracy 3% (Full span) 14-5-7 7 Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 q i o !4 q o i !

Description IR1000 IR1010 IR1020 IR2000 IR2010 IR2020/2120 IR3000 IR3010 IR3020/3120 P362030-201 Bracket P36201023 P36202028 Pressure gauge234 G33-2-01 G33-10-01 G43-2-01 G43-10-01 G43-2-01 G43-4-01 G43-10-01 G33-4-01 G43-4-01 1 A bracket and two mounting screws (M5 x 35) To mount the bracket, remove two body screws (M5 x 30) on the name plate on the opposite side and replace the attached

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

Series P port/Thread VV2Q22-05 1 set Manifold part No. 2 3 VQ20 VQ30 Rc3/8 NPT3/8 NPTF3/8 G3/8 VQ21M1-5G-C6 00N 00T 00F 4 sets Valve part No. (Stations 1 to 4) Stations VQ21M1-5G-C8 1 set Valve part No.

2 Port for Oil Dimensions (mm) (N.C.) 1in = 25.4mm Grommet: G Conduit: C Approx. 300 V D Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port

2 Port for Oil Dimensions (mm) (N.C.) 1in = 25.4mm Grommet: G Conduit: C Approx. 300 V D Approx. 280 D F Approx. 300 F Q Q Class H coil Broken line section C C G 1/2 R R E E A H A H B B 2-P Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port

Valve For VCW20 OR-1860-120Nil: NBR F: FKM E: EPDM P: PTFE OR-2380-130For VCW30 Nil: NBR F: FKM E: EPDM P: PTFE OR-2600-180For VCW40 e Nil: NBR F: FKM E: EPDM P: PTFE Manifold For VCW20 r OR-1400-178Nil: NBR F: FKM E: EPDM P: PTFE OR-2670-178When the loosened clip is pulled out in direction e using pinchers, etc., the coil can be removed and replaced in direction r.

(mm) A B C D E F G H J L Port size Bracket part no.

Q1 5 4 () 1) () Q2 1)+COM (4) 7) (2)1U (3)J1,J2, Q2 (11) (P ) L L 0.3m 0 (M5x0.8) LO L 2 4 3 6 (5) 5 4 2) B (12) (2):1U 2)(3)Q1 8) (3)Q2 Assy N C 3) ) (6) ( D [kPa] (2):3M EA NPN2 9) 8) (PD) EB PNP2 0 to -100 EC NPN1 + S EE PNP1 + C FA NPN2 D FB PNP2 -100 to 100 8)VQ100 Ass yP.41 FC NPN1 + FE PNP1 + (3)Q2 (4)LO 9)(3)J1,J2Q2 P.6 (3)C 4) F 3) ZFC 4

G Pressure gauge*7 E Vacuum pressure switch (Vacuum 2 outputs) F Vacuum pressure switch (Compound pressure 2 outputs) !

Six station manifrcld ass'y: sta. 1-4) NVF'I'10-5G-017 sta. 5-6) NVF1 10-3G-017 NW3F1 -30-061-017 No. ot Stgliorg I l 5 I F Mounting Brackets tPoding 01 ,d' NPIF DltrlENSlON D E F G H J x ll ta o P n s T u w x z AA BB 3.78 (96) 3.41 1.77 (,r5)0.39 (10) o.59 (15) 0.20 (5) 0.63 (16) 1.O2 (28t 3.50 (89) 1 . 1 8 (30) 0.59 (15) 2.76 (70) o.87 (21) o_20 {5) 1 . 1 8 {30} 0.67 ltTl 0.59 (ls) o.32

Six station manifrcld ass'y: sta. 1-4) NVF'I'10-5G-017 sta. 5-6) NVF1 10-3G-017 NW3F1 -30-061-017 No. ot Stgliorg I l 5 I F Mounting Brackets tPoding 01 ,d' NPIF DltrlENSlON D E F G H J x ll ta o P n s T u w x z AA BB 3.78 (96) 3.41 1.77 (,r5)0.39 (10) o.59 (15) 0.20 (5) 0.63 (16) 1.O2 (28t 3.50 (89) 1 . 1 8 (30) 0.59 (15) 2.76 (70) o.87 (21) o_20 {5) 1 . 1 8 {30} 0.67 ltTl 0.59 (ls) o.32