Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 5-Port Valve, Actuation: Double, Status at Power Off: Self-Retaining, Valve Positions: 2-Position Normally Open, Pipe Port Type: G, Port Size: 1/8, Connecting Tube Diameter: -, Pressure Rating(MPa): 0.1 to 0.7, Driving Type: Pilot Type Spool
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Surge Suppressor: Light & Surge Suppressor Non-polar, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: G, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M Plug Connector w/o Lead Wire, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: G, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: L Plug w/o Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: G, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M Plug w/o Connector, Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: G, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: Grommet Lead Wire 0.3m, Surge Suppressor: None, Manual Override: Push-turn Locking Slotted Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: G, Option: -, CE Compliant: -
Function: 2 Position Double, Piping: Body Ported, Exhaust: Individual, Specifications: Standard, Voltage: 24VDC, Lead Wire: M Plug w/o Connector, Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: Base Mounted w/Sub-plate 1/8, Body Ported 1/8, Thread: G, Option: -, CE Compliant: -
Test range Thermometer Test equipment Pressure tap Pressure tap Throttle valve on the upstream side Flow meter Throttle valve on the downstream side 2d 6d 20d 10d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 12 VXB Series Flow Rate Characteristics Note) Use this graph as a guide. If an accurate flow rate is required, refer to pages 8 to 12.
VXZ VXS VXB Test range Thermometer VXE Equipment for test Pressure tap Pressure tap VXP VXR Throttle valve in the downstream side Flow meter Throttle valve in the upstream side VXH 2d 6d VXF 20d 7d VX3 Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005-2-3 VXA 100 100 Saturated steam flow rate Q0 [kg/h] (when Kv = 1) Upstream pressure Water flow rate Q0 [L/min] (When Kv = 1) 50 40
Test range Thermometer Equipment Pressure Pressure for test tap tap Restrictor Flow Restrictor on the 2d 6d on the meter downstream side upstream side r 20d r 10d Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005 32 Series VXN Flow-rate Characteristics Note) Use this graph as a guide. In the case of obtaining an accurate flow rate, refer to pages 28 through to 32.
VXZ VXS VXS VXB Test range Thermometer VXE Equipment for test Pressure tap Pressure tap VXP VXR Throttle valve in the downstream side Flow meter Throttle valve in the upstream side VXH 2d 6d VXF 20d 7d VX3 Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005-2-3 VXA 100 100 Saturated steam flow rate Q0 [kg/h] (when Kv = 1) Upstream pressure Water flow rate Q0 [L/min] (When Kv = 1) 50
60C, Ambient temperature: 32C Water cooled aftercooler Inlet air temperature: 180C Inlet temperature of cooling water: 30C Note 2) Series IDF Inlet air temperature: Saturated at 35C (IDF1D), saturated at 40C (IDF2D to 240D), Ambient temperature: 32C Note 3) Series IDG Inlet air temperature: Saturated at 25C, Ambient temperature: 25C Note 4) Series IDU Inlet air temperature: 60C (IDU3D to 6D
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D
D 6D 1 mm 6 < D 25D 2 mm D > 25D 4 mm 3) In case of a double rod type and a single acting retraction type, enter the dimension with the rod retracted. 4) In case of a double rod type, the change is applicable to a single side only.
Test range Thermometer Test equipment Pressure tap Pressure tap Throttle valve on the Flow meter Throttle valve on the downstream side 2d 6d upstream side 20d 7d Fig. (3) Test circuit based on IEC 60534-2-3, JIS B 2005-2-3 100 100 Saturated steam flow rate Q0 [kg/h] (when Kv = 1) Upstream pressure Water flow rate Q0 [L/min] (When Kv = 1) 50 40 40 50 P1 = 1 MPa P1 = 0.8 MPa P1 = 0.6 MPa
This is a legacy product, and replaced byVFR2410-6D
D O U B L E A C T I N G T Y P E: 10~25 Lubrication Not required Action Double Acting type, Single Acting type (N.O) Auto Switch See Accessories P R O D U C T S E L E C T O R (H O L D I N G F O R C E) Action Model Bore Size (mm) Holding Force @0.5MPa / 73PSI (Effective) (N) Opening Stroke (Included) (mm) P A R A L L E L T Y P E S I N G L E A C T I N G T Y P E: N O R M A L LY O P E N MHQ2-6D
CAT.EX30-1 A Stainless Steel Heat Exchanger Type Air Dryer Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740
Stainless Steel Heat Exchanger Type Air Dryer Series IDUS Series IDUS Inlet air temperature C Model IDUS3E IDUS4E IDUS6E 500 310 55 740 Air flow capacity l/mim(ANR) 295 (300) 475 (430) 703 (640) 60 160 275 225 55 Power consumption W 165 (189) 230 (275) 280 (295) 60 ( ): Previous model IDU3D/4D/6D Series IDFS Series IDFS Inlet air temperature C Model IDFS6E IDFS8E IDFS11E 740 35 1200 1650