FF FG FF FC Attachment mounting thread FE thread depth FH FC FG FF FA FB With adjuster With scraper Hexagon width across flats RB 2-M5 x 0.8 Supply port RA Stroke adjuster SA Hexagon width across flats RC RD SC At the maximum stroke RE Arrangement range RF SB Maximum adjustment dimension RJ Note) Observe the specified adjustment range when adjusting with a stroke adjuster.
FF FG FF FC Attachment mounting thread FE thread depth FH FC FG FF FA FB With adjuster With scraper Hexagon width across flats RB 2-M5 x 0.8 Supply port RA Stroke adjuster SA Hexagon width across flats RC RD SC At the maximum stroke RE Arrangement range RF SB Maximum adjustment dimension RJ Note) Observe the specified adjustment range when adjusting with a stroke adjuster.
AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-T AS-D AS-T ASP ASN AQ ASV AK VCHC ASS ASR ASQ 591
AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 743 Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting ASDF-D Series RoHS Model Applicable tubing O.D.
Description Material AS-FG Reference dimensions AS-FP 1 2 3 4 Body Valve Cap Needle Aluminum alloy NBR Rolled steel Brass POM Zinc alloy AS-FM AS-D AS-T 5 Handle Replacement Parts ASP No. Part no.
When using a commercially available switching regulator, be sure to ground the FG terminal. Atmospheric release port 4. In locations where the switch is exposed to water and dust, etc., these may enter the switch from the atmospheric release port.
5 q AS-FG AS-FP AS-FM AS-FM AS-D AS-T ASP !9 !1 q !2 t !0 !1 u !2 t !0 i ASN AQ Component Parts Component Parts Material Description Note Description No. Note Material No.
CANH V+ 24 V V0 V CANL FG CANH V+ BDH BS+ BDL BS24 V 0 V BDH BS+ BDL BS24 V 0 V 24 V Master unit Terminal resistor SI unit SI unit DG DB DA DG DB DA DG DB DA Terminal resistor Master VConector with terminal resister SLD FG FG FG BDH CANL BDL FG CANH with shield Twisted pair Type 3 ground Type 3 ground Type 3 ground V+ Branch crimped connectors 1-3-34 35 Cassette Type Manifold Serial Transmission
CANH V+ 24V V0V CANL FG CANH V+ BDH BS+ BDL BS24V 0V BDH BS+ BDL BS24V 0V 24V Master unit SI unit SI unit DG DB DA DG DB DA DG DB DA Master Connector with terminating resistance VSLD FG FG FG BDH CANL BDL FG CANH Class 3 ground Class 3 ground Class 3 ground Crimped connectors for junction Twisted pair with shielding V+ Terminating resistor 30 Cassette Type Manifold Series SZ3000 SI unit
RESET GND FG Connect to GND of the counter cable. RESET Reset signal is output. Connect to RESET of the counter cable. FG FG terminal. Connect to FG of the counter cable. 6.2 Counter plug wiring The wiring of the counter cable (LATH3-) and Multi-counter (CEU5) is shown below. Refer to the Multi-counter (CEU5) operation manual for further details.
FG Phase A A-phase pulse signal is output. Red Connect to Phase A of the counter cable. GND Sensor input common. Light Grey Connect to GND of the counter cable. RESET Reset signal is output. Yellow Connect to RESET of the counter cable. FG FG terminal.
CANH V+ 24V V0V CANL FG CANH V+ BDH BS+ BDL BS24V 0V BDH BS+ BDL BS24V 0V 24V Master unit SI unit SI unit DG DB DA DG DB DA DG DB DA Master Connector with terminating resistance VSLD FG FG FG BDH CANL BDL FG CANH Class 3 ground Class 3 ground Class 3 ground Crimped connectors for junction Twisted pair with shielding V+ Terminating resistor 25 Series SZ3000 Dimensions/SZ3000: Serial Transmission
1 Speed Controller with One-touch Fitting Stainless Series Series AS-FG Elbow Type/Universal Type Stainless specifications for use in corrosive environments. Stainless steel 303 used for metal parts.
DATA SET1 2 OUT 1 2 3 SET MONOSASHIKUN Shielding should be connected to FG (frame ground).
0 r FG Frame ground (Tighten the screw with the washer when mounting the controller. Connect the ground wire.) !1 !
Signal description Detail Signal description Details 24V 0V FG Home position switch (+) Home position switch (OUT) Home position switch () Limit switch (+) Limit switch (OUT) Limit switch () N.C. N.C.
(A clearance of 40 or more is required.) 60 (96.7) (60) (49.6) 110.8 35.5 132.2 94 96.7 35.5 Motor 100 60 102 60 42 170 163 108.7 67 22.2 Controller 60 34 31.8 48.7 4-9.5 counterbore depth 5.4 5.5 through 19.5 FG terminal M3 Workpiece mounting center line 5 15.5 5 7 4-M5 x 0.8 depth 9 7.1 (Max. 10.1) 17.5 37 (51.8) 87.3 T-slot section for mounting 198 + Stroke 6 8.5 5.3 3 Motor position TA
Connect the shield wire to FG (flame ground). 2. The maximum transmission distance for the stroke reading cylinder is 23 m, but since the output signal is a pulse output, the sensor cable should be wired separately from other power lines.
Host Computer Thermo-con RS-485 RS-485 Symbol Pin No Symbol FG Connector shell FG + 1 + 9 SG 5 FG Figure1-1 Communication Connection (RS-485) Host Computer Thermo-con RS-232C RS-232C Symbol Pin No Symbol FG Connector shell FG RD 2 RD SD 3 SD SG 5 SG RS Short CS Figure1-2 Communication Connection (RS-232C) 1-1 HECR Specifications of Communication Method 2 Specifications of Communication Method