Series: 542 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: B (N.O., Normally Open), Bracket
Series: VP300, Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/4, Thread Type: NPT, Actuation Type: N.O., Normally Open, Bracket: Bracket, Made to
Series: VP500, Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/4, Thread Type: NPT, Actuation Type: N.O., Normally Open, Bracket: Bracket, Made to
Series: VP500, Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/4, Thread Type: NPT, Actuation Type: N.O., Normally Open, Made to Order: X500 [Pilot Exhaust Port w/Piping Thread
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation: B (N.O., Normally Open)
Series: 544 (VP500), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: B (N.O., Normally Open), Made to Order: X500 [
Series: VP500, Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: Conduit Terminal, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/4, Thread Type: NPT, Actuation: N.O., Normally Open
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure on the upstream side Test equipment Pipe for measuring pressure on the downstream side Fig.
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Pipe for measuring temperature Pipe for measuring pressure in the upstream side Equipment for test Pipe for measuring pressure in the downstream side
Pressure gauge or pressure convertor Thermometer Differential pressure gauge or differential pressure converter Pressure control equipment d1 d33d1 Flow control valve 3d3 d2 Air supply Filter Shut off valve Flow meter 3d2 10d2 3d1 10d1 10d3 Equipment for test Pipe for measuring temperature Pipe for measuring pressure in the upstream side Pipe for measuring pressure in the downstream side
0 3 0 3 0 3 0 Supply port Supply port Supply port P P P P P T T T T U T U U U U E L E E E E L S L L L S S S S L L L L L 6 9 6 9 6 9 6 9 6 9 IN IN IN MPa MPa MPa MPa MPa Right Left Right Bracket DIN rail mounting bracket DIN rail mounting bracket Stations 1 Stations 1 Stations 1 2 3 IISA2NSR-1B1 set (1 station manifold part number) ISA2-GE41P1 set (Air catch sensor part number) IISA2NSR-3D1
This is a legacy product, and replaced byVF5120-3D1-03
This is a legacy product, and replaced byVF3133-3D1-02
This is a legacy product, and replaced byVF3233-3D1-02
This is a legacy product, and replaced byVF3130-3D1-02T, VALVE, PILOT *LQA, VALVE, VF3000 SOL VALVE 4/5 PORT, ED, VF3000 BODY PT 1/4NPT (F), .46200 lb
This is a legacy product, and replaced byVF3133-3D1-02N
This is a legacy product, and replaced byVF5120-3D1-03T, VALVE SOL/PILOT *LQA, VALVE, VF5000 SOL VALVE 4/5 PORT, GD, VF5000 BODY PT 3/8NPT (F), .83600 lb
0.3 0.2 0.1 0.3 0.2 0.1 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 Right Right Left Bracket DIN rail mounting bracket DIN rail mounting bracket Stations 1 Stations 1 Stations 1 2 3 IISA2NSR-1B1 set (1 station manifold part number) ISA2-GE41P1 set (Air catch sensor part number) IISA2NPL-1D1 set (1 station manifold part number) ISA2-GE41N 1 set (Air catch sensor part number) IISA2NSR-3D1
0.3 0.2 0.1 0.3 0.2 0.1 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 Right Right Left Bracket DIN rail mounting bracket DIN rail mounting bracket Stations 1 Stations 1 Stations 1 2 3 IISA2NSR-1B1 set (1 station manifold part number) ISA2-GE41P1 set (Air catch sensor part number) IISA2NPL-1D1 set (1 station manifold part number) ISA2-GE41N 1 set (Air catch sensor part number) IISA2NSR-3D1
SMC's VP300/500/700 series solenoid valve, offers high flow capacity and reduced power consumption (1.55W standard, 0.55W with power saving circuit). The series may be used as either a selector valve, or a divider valve. It is vacuum applicable up to –101.2kPa. Series VP3145/3165/3185 is a large size, 3 port solenoid valve with a rubber seal. It is possible to use the series in vacuum