Series: 742 (VP700), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Bracket: F (Bracket)
Series: 742 (VP700), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 1 (100VAC, 50/60Hz), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Bracket: F
Series: VP700, Pilot Type: External Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: Conduit Terminal, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: Rc, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: -
Series: VP700, Pilot Type: External Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: Grommet, 300mm Lead Wire Length, Light & Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: Rc, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: -
Series: VP700, Pilot Type: External Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 3 [110VAC (115VAC), 50/60Hz], Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: Rc, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order
Series: VP700, Pilot Type: External Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 24VDC, Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: Rc, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: -
Series: VP700, Pilot Type: External Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 100VAC, 50/60Hz, Electrical Entry: DIN Terminal w/Connector, Light & Surge Suppressor: Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 1/2, Thread Type: Rc, Actuation Type: N.C., Normally Closed, Bracket: Bracket, Made to Order: -
Station Address S1 S2 00H to 02H: Disabled 0 0 to 2 (Do not use these addresses.) 03H (Factory setting) 0 3 04H 0 4 EFH E F F0H to FFH: Disabled F 0 to F (Do not use these addresses.) (2) Settings of the DIP Switch S3 The following table shows the settings of the DIP switch (S3). Switch No.
Bit 3 of SW2 SW1 Station Address Bit 3 of SW2 SW1 Station Address OFF 0 Disabled ON 0 50H OFF 1 41H ON 1 51H OFF 2 42H ON 2 52H OFF 3 43H ON 3 53H OFF 4 44H ON 4 54H OFF 5 45H ON 5 55H OFF 6 46H ON 6 56H OFF 7 47H ON 7 57H OFF 8 48H ON 8 58H OFF 9 49H ON 9 59H OFF A 4AH ON A 5AH OFF B 4BH ON B 5BH OFF C 4CH ON C 5CH OFF D 4DH ON D 5DH OFF E 4EH ON E 5EH OFF F 4FH ON F 5FH Turn the power
Both series are available in a normally closed or normally open styles.3 port, pilot poppet type valve , Available with power saving circuit to reduce power consumption , Port sizes from 1/8 to 1/2, depending on series , Thread types: Rc, G, NPT, NPTF, REPAIR KIT (VP742/VP742R), VALVE, VP3/5/7 SOL VALVE 3-PORT, J1, VP3/5/7 BODY PT 1/2, .09240 lb
How to Order Needle Valve/Flow Rate Characteristics 0 2 F A 1 AS 1 M3 X790 06 AS1201F-M350 45 40 35 30 25 20 15 10 5 0 0.5 0 1 1.5 2 2.5 3 3.5 4 4.5 5 6 7 8 Inlet pressure: 0.5 MPa Port size Push-lock type Body size Flow rate [L/min (ANR)] 1 M3 x 0.5 M3 M3 x 0.5 Applicable tubing O.D.
This is a legacy product, and replaced byVP742-5DZ1-04A-F
This is a legacy product, and replaced byVP742-5YZ1-04A-F
This is a legacy product, and replaced byAS2201F-U01-04A, FLOW CTRL, UNIFIT, METRIC TUBE, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, 1X, AS***F OTHER SIZE RATING, .03750 lb
The latest version can be found hereVP742-5D1-04A-F, VALVE, SOL, VALVE, VP3/5/7 SOL VALVE 3-PORT, JA, VP3/5/7 BODY PT 1/2, 1.50648 lb, ModelPressure specificationsResponse time ms (at 0.5 MPa) Without light/surge voltage suppressorWith light/surge voltage suppressorAC S, Z typeR, U typeVP742Standard (0.2 to 0.7)19 or less44 or less22 or less44 or less
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Drip-Proof / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: [Rc (R)] Rc, Port Size: 1/2, Pressure Rating(MPa): -0.1~0.7, Driving Type
Series: 742 (VP700), Pilot Type: R (External Pilot), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal w/Connector), Light & Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread Type: Rc, Actuation Type: A (N.C., Normally Closed), Bracket: F (Bracket)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com