D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT () Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+)
D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT () Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+)
V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
D-A90V OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT ( ) Blue (g) Weight D-A93V D-A96 D-A96V D-A90 D-A90V D-A93 D-A93V Model 8 8 Lead wire length: 0.5 m 6 6 6 6 LED Brown (Red) OUT (+) Brown Contact protection box CD-P11 CD-P12 41 41 Lead wire length: 3 m 30 30 30 30 Resistor Reed switch Zener diode Dimensions OUT () Blue D-A90, D-A93, D-A96 Blue (Black) D-A96V DC (+
41 0 0 1.5 2 2 5.5 4 4.5 8 31.5 35.5 43 31.5 35.5 43 Note) The above values should be used as a guide for detection at stroke end.
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 12 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 2 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 3 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 4 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 5 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 6 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 7 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 8 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 10 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 15 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 17 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 20 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 16 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Manifold Type: 41 (Base Mounted), Valve Stations: 9 Stations, A, B Port: M5T (10-32 Nom)
Manifold Type: 41 (Base Mounted), Valve Stations: 16 Stations, A, B Port: M5T (10-32 Nom)