Solenoid: No.3 Solenoid, Body Size: 9 (50A), Style: 2 (Energized Closed/N.O.), Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: N (NPT), Voltage: 7 (240VAC 50/60HZ), Lead Wire: D (DIN Connector)
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 24VDC, Lead Wire: Conduit, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: Light & Surge Suppressor
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 110VAC 50/60HZ, Lead Wire: Grommet, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 220VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPTF, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPTF, Voltage: 110VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPTF, Voltage: 24VDC, Lead Wire: DIN Connector, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 24VDC, Lead Wire: Grommet, Surge Suppressor: -
Solenoid: No.3 Solenoid, Body Size: 50A, Style: Energized Closed/N.O., Option: BC6, Copper Body & Shading Coil, NBR Seal, Class B Coil, Port Size: 20 [2 (50A)], Thread: NPT, Voltage: 240VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: -
High temp. cut off alarm ERR12 Low temp. cut off alarm ERR13 Unused Output failure alarm ERR15 D2 23 22 21 20 Upper temperature limit alarm WRN Lower temperature limit alarm WRN Thermostat alarm ERR14 DC power supply failure alarm ERR11 D3 23 22 21 20 External sensor failure alarm ERR18 Internal sensor failure alarm ERR17 During Auto tuning or auto tuning warning ERR19 Flow switch alarm
High temp. cut off alarm ERR12 Low temp. cut off alarm ERR13 Unused Output failure alarm ERR15 D2 23 22 21 20 Upper temperature limit alarm WRN Lower temperature limit alarm WRN Thermostat alarm ERR14 DC power supply failure alarm ERR11 D3 23 22 21 20 External sensor failure alarm ERR18 Internal sensor failure alarm ERR17 During Auto tuning or auto tuning warning ERR19 Flow switch alarm
(Conforming to DIN) Clip Without indicator light AXT100-20-1 Rated voltage With indicator light 16.8 Voltage symbol Part no. AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.
(b) OFF ON OFF 63.4% CDT = 100 ms 100 50 100 4.00 10.00 4.00 120 84 120 3000 4000 3000 20 50 20 1 50 60 50 1 50 60 50 1 0.20 0.15 0.20 1 0.20 0.15 0.20 2 20 30 20 2 20 30 20 2 0.10 0.05 0.10 2 0.10 0.05 0.10 (2) (a) PB06 GD2 4.00 [] PB08 PG2 120 [rad/s] PB09 VG2 3000 [rad/s] PB10 VIC 20 [ms] PB29 GD2B 10.00 [] PB30 PG2B 84 [rad/s] PB31 VG2B