Note 2) Replacement part numbers correspond to the item numbers in the figures. 14-5-18 18 Precision Regulator Series IR1000/2000/3000 Dimensions IRV1000-01 IRV2000-02 53 55 16.5 2.3 30 22 2.3 41 (R) F.R.L.
Refer to"LECSC2-T Operation Manual, chapter 6 for details of each parameter. -22- 5.3.1 Change of parameter block To enable settings for all parameters. Select Basic settings (list) tab and change PA19 value to 000C. Click the PA19 row then click Selected Items Write. Cycle the power off, then on for parameters for this driver to be enabled. Please click Read".
Q2 +COM 30.30.4 4 L L 5 DC24V LO L 6 DC12V M M 5 MO M 5 4300 5MMO 6 B 6() 9 - No.ZB-OM00301 / kPa / P1 0-101 15V2F.S.7 P3 -100100 15V2F.S.7 8 EA EAM SI 9 NPN2 EAP [psi] 8 0-101 8 EB EBM SI 9 PNP2 EBP [psi] 8 8 FA FAM SI 9 NPN2 FAP [psi] 8 -100100 8 FB FBM SI 9 PNP2 FBP [psi] 8 73m 8 9kPa G 2m V 10 11 12 C2 2 B C4 4 N1 1/8 N3 5/32 K 12 L2 2 L4 4
When setting, allow 7 digits or more between P1 and P2 (and P3 and P4). Less than 7 digits will not allow correct operation. This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenace of such equipment.
IBV1 Series SMC Corporation 1.Index 1Table of contents P1 2Specifications P2 3Features P2 4External dimensions drawing P3 5How to mount a nozzle P4 6Relationship between Upstream Piping and Peak Pressure P5 7Safety Instructions P6~10 1 2.
*, ACTUATOR, AUTO-SWITCH BRACKET, 22, AUTO-SWITCH BRACKET, .00000 lb
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: G (Grommet w/0.3m Lead Wire), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure Supply, P Port: M (w
Main Body Shape: Unit, Additional Function: Filter, Ultimate Vacuum(kPa): -74, Air Consumption Flow Rate(l/min): 12, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: -, Air Supply Port One-Touch Fitting Size: -, Application: Manifolds, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature Range(°C): 5
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: LO (L Plug Connector w/o Connector, Light/Surge Voltage Suppressor), Manual Override: B (Locking Type), Suction Filter: None, Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S.), Air Pressure
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S.), Air
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/o Connector, Light/Surge Voltage Suppressor, Manual Override: Locking Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port: w/o Supply
Nozzle Nominal Size: ø0.5, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply, P
Vacuum ejector series ZA is compact and lightweight, making it ideal for pick and place operations, and suitable to all industries. Due to the compact design of the ZA, it is possible to install on moving parts. The shortened tube length to pad improves response time. The ZA is available as a single unit or manifold type, with or without pressure sensors and suction filters. Compact
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: G (Grommet w/0.3m Lead Wire), Manual Override: Non-locking Push Type, Suction Filter: F (Suction Filter), Pressure Sensor Specs: P1 (Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S.), Air Pressure Supply, P Port: 2 (ø4
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: J1 (Supply: NC, Release: None), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: G (Grommet w/0.3m Lead Wire), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: B (w/o Pressure Sensor), Air Pressure Supply, P Port: 2 (ø4, Straight), Vacuum, V Port: 2 (ø4, Straight
Nozzle Diameter: ø0.7, Exhaust: Silencer for Single Unit, Solenoid Valve Combination: Supply Valve: N.C.; Vacuum Release Valve: None, Voltage: 24VDC, Electrical Entry: Grommet Lead Wire 0.3m, Manual Override: Non-locking Push Style; Latching: Push Lock Type, Vacuum Pressure Switch Suction Filter: 100 to -100kPa/PNP Open Collector 2 Outputs, Suction Filter, Vacuum Pressure Switch Unit Specs
Main Body Shape: Unit, Additional Function: -, Ultimate Vacuum(kPa): -78, Air Consumption Flow Rate(l/min): 28, Vacuum Port Connecting Port Shape: One-Touch Couplings, Vacuum Port One-Touch Fitting Size: Ø4, Air Supply Port Connecting Shape: One-Touch Couplings, Air Supply Port One-Touch Fitting Size: Ø4, Application: Individual Item, Operating Pressure Range(MPa): 0.2~0.5, Operating Temperature
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: None, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: Grommet w/0.3m Lead Wire, Manual Override: Non-locking Push Type, Suction Filter: Suction Filter, Pressure Sensor Specs: Pressure Sensor, 0 to -101kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port: ø4, Straight, Vacuum, V Port
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: K1 (Supply: NC, Release: NC), Pilot Valve: Standard (1W for DC), Power Supply Voltage: 5 (24VDC), Electrical Entry: L (L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: P3 (Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S.), Air Pressure
Nozzle Nominal Size: ø0.7, Solenoid Valve Combination: Supply: NC, Release: NC, Pilot Valve: Standard (1W for DC), Power Supply Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor, Manual Override: Non-locking Push Type, Suction Filter: None, Pressure Sensor Specs: Pressure Sensor, -100 to 100kPa, Accuracy ±2% F.S., Air Pressure Supply, P Port